Fuse Replacement - Chicago Electric 91813 Instructions

Plug-in power inverter, modified sinewave type; 12 vdc input; 120 v~, 100 (peak) /60 (cont.) w nominal output; operating temp. range: 14°-113° f

Advertisement

it becomes abnormally hot, do not use this device with the Inverter.
9.
This device is designed for use in 12 VDC, negative ground systems only.
10.
allow adequate ventilation. Do not cover this unit while it is plugged in.
unit generates heat; without proper ventilation it may overheat, potentially causing
a fire hazard.
11.
leave this device unplugged whenever the car's engine is turned off.
prevent draining and perhaps damaging the battery, only plug this device in while
the car's engine is on.
12.
Switch off the unit to be powered before being plugging into this device.
13.
Do not use this device if under the influence of alcohol or drugs.
labels if taking prescription medicine to determine if your judgment or reflexes are
impaired while taking drugs. If there is any doubt, do not use this device.
14.
Stay alert.
if you are tired.
15.
Do not run engine indoors, in a garage, or any other structure.
is produced by running engines and is DeaDly in a closed environment. Early
signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness,
or nausea. If you have these signs, get fresh air immediately.
16.
The warnings, precautions, and instructions discussed in this instruction sheet
cannot cover all possible conditions and situations that may occur. It must be
understood by the operator that common sense and caution are factors which
cannot be built into this set, but must be supplied by the operator.
1.
Before starting make sure that the car's engine is running (in an open area, see
Warning #15, above), the car is stopped, the transmission is in park/neutral, and
the parking brake is set. Make sure that the circuit that the Inverter will be plugged
into is fused for 10 Amps or greater.
2.
Plug the Inverter into the cigarette lighter type socket. If the Inverter has a difficult
time going into the socket, the switch on the side of the plug may need to be put in
the "S" position. If the Inverter fits loosely, turn the switch to the "L" position. Do
not use the inverter if it does not fit properly. Have a qualified technician inspect
the plug and socket and install a new socket if necessary.
3.
The green LED power indicator on the end of the inverter should light up.
4.
With the device switched off, insert the device's plug into the socket.
5.
After use, remove the Inverter from the socket and store in a dry area away from
children.
6.
While being careful not to lose the terminal or nut, unscrew the nut on the end of
the inverter's plug.
7.
Remove the old fuse and replace with another 10 Amp fuse of the same type.
8.
Replace the terminal and nut and tighten.
Watch what you are doing, use common sense. Do not use this device
Operation Instructions

Fuse Replacement

This
To help
Read warning
Carbon monoxide
ReV 06h