GE JV535 Owner's Manual And Installation Instructions page 12

Range hoods vented
Table of Contents

Advertisement

9
MARK HOLES
Select the vent option that your installation will
require and proceed to that section:
A. Outside top exhaust
(Vertical duct–3
1
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hood mounting screws (4)
13
15
/
" (30" hood)
16
16
15
/
" (36" hood)
16
Cabinet front
Cabinet Bottom
5
1
/
"
4
Vertical duct
5"
access hole
1
1
/
"
4
Wood shims
(recessed-
Center
bottom cabinets only)
B.Outside top exhaust (Vertical duct–7
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hood mounting screws (4)
13
15
/
" (30" hood)
16
16
15
/
" (36" hood)
16
Cabinet front
Cabinet
bottom
Access
"
hole for 7
round duct
Wood shims
(recessed-
Center
bottom cabinets only)
line
C.Outside rear exhaust
(Horizontal duct–3
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Wood shims
(recessed-bottom cabinets only)
Cabinet front
Horizontal duct
3
3
/
"
4
access hole
Cabinet
5
1
bottom
13
15
/
" (30" hood)
16
16
15
/
" (36" hood)
16
Hood mounting screws (4)
Installation Instructions
"
"
/
x 10
Rectangular)
4
13
15
/
" (30" hood)
16
16
15
/
" (36" hood)
16
12
9
/
"
16
5
1
/
"
4
2"
1
1
/
4
Electrical access hole
(in cabinet bottom)
line
"
Round)
13
15
/
" (30" hood)
16
16
15
/
" (36" hood)
16
12
1
/
"
2
"
8
DIA.
1
1
/
"
HOLE
4
5"
1
1
/
2
Electrical access
hole
(in cabinet bottom)
"
"
1
/
x 10
Rectangular)
4
1
/
"
1
7
/
"
8
16
/
"
5
1
/
"
4
4
12
7
/
"
16
13
15
/
" (30" hood)
16
16
15
/
" (36" hood)
16
Electrical access hole
Center line
(in wall)
D. Recirculating (non-vented ductless–
Available on JV5 Series models only)
• Use the hood as a template and mark the locations
on the cabinet for the electrical wiring and keyhole
screw slots.
• Since the hood is to be recirculated (not to be vented
outside), do not cut out any vent openings in the wall
or cabinet bottom.
CHOOSE VENTING OPTION
10
(for JV5 Series models only)
The hood can be set to vent outside or to recirculate
air back into the kitchen.
The plastic vent lever is located near the center of the
10
1
/
"
2
hood opening.
To vent to the outside, make sure the plastic vent
"
lever is in the HORIZONTAL position (flat against
the metal top of the hood).
To recirculate air into the kitchen, make sure the
plastic vent lever is in the VERTICAL position
(flat against the plastic blower housing).
NOTE: In order to change the vent lever position,
you will need to pull the lever out slightly to clear
the plastic tabs.
outside venting
10
1
/
"
2
"
1 Ft = 0.3 m
1" = 2.5 cm
12
Set for
Set for
recirculating
Stop tab
Stop tab
Hood shown lying upside down

Advertisement

Table of Contents
loading