Clifford 10.5X Installation Manual page 28

Car security
Hide thumbs Also See for 10.5X:
Table of Contents

Advertisement

3-3 FACTORY DISARM WITH CHANNEL 2 (ON)/FACTORY DISARM WITH CHANNEL
2 (OFF): The factory alarm disarm wire sends out a pulse when activating channel 2 output.
3-4 GROUND WHEN ARMED IN VALET (ON)/GROUND WHEN ARMED IN VALET
(OFF): Provides On/Off programming for the Ground When Armed wire output when locking the
car while in Valet mode.
3-5 CHANNEL 3 VALIDITY (ON)/LATCHED/LATCHED, RESET WITH IGNITION/30-
SECOND/60-SECOND/90-SECOND TIMED/REMOTE START REPORT: Channel 3 can
be programmed for these output configurations. The unit is set to the default validity output. To
change the configuration, use the two-chirp setting to toggle to the different configurations.
NOTE: Reference H2/4 discussion.
This option is designed to reduce the installation time for add-on remote starters.
N N o o t t e e : : Only channel 3 has this capability and the zone 1sensor shunt connection must be made for this
feature to work correctly.
Remote start ON report: When programmed on and channel 3 is transmitted the system will:
1. Bypass the zone 1 input and monitor for ground.
2. Bypass zone 2, 4, & 7 inputs as long as zone 1 is grounded.
3. Send the factory alarm disarm output.
4. Activate the starter kill as an anti-grind circuit.
5. Monitor and bypass the zone 3 door switch input in the same way as door trigger error bypass.
6. Transmit the remote start ON notification to the HHU.
Remote start OFF report: When programmed on, and ground on, zone 1 ceases and the system will:
1. Monitor the zone 1 input for triggers
2. Re-activate the zone 2, 4, & 7 sensor inputs.
3. De-activate the starter kill as an anti-grind circuit.
4. Monitor and bypass the zone 3 door switch input in the same way as door trigger error bypass.
5. Transmit the remote start OFF notification to the HHU.
3-6 CHANNEL 3 LINKING (NONE)/ARM, DISARM, BOTH: When programming to validity or
timed output this can be programmed to activate when arming or disarming (or both) with the transmitter.
3-7 CHANNEL 4 VALIDITY (ON)/LATCHED/LATCHED, RESET WITH WITH
IGNITION/30-SECOND/60-SECOND/90-SECOND TIMED: Refer to discussion for H2/4.
28
©