Of Dome Device - Honeywell HSD-361P Operation Manual

Vista series hsd speed dome
Table of Contents

Advertisement

Short-cut operation and specification of dome device
Problem Description
S.N.
After power on,
1
No motion and no image.
After power on, the dome
device rotate normally,
2
but no character nor image
display.
After self-test of the dome
3
device, menu cannot be
displayed
Distorted character or
4
image
After
power
5
self-test
and
locked
Cannot stop pan rotation
(rotate
and
6
alternatively)
After normal working, it
7
will rotate one circle when
being controlled
Vertical range is not within
8
90 ± 2 degree with large
deviation
Self-test is normal, but
9
cannot control
Insensitive control of dome
10
device
Call out function fails
11
Auto
action
12
device periodically
One dome working well
13
while the other does not
under identical operation
24
Possible Reason
Power cable is connected improperly
Fault of power PCB of dome device
slip ring power wires disconnected
Fault of main control board
Character monitor switch is off
Improper connection between camera and
dome device
wrong operation
Fault of OSD control board
Interfered by exterior electronic signal
(noise) or the camera is directed to the
monitor screen
System wrong function
The system setting is start self-test after
on,
no
receiving command and you can see the
motor
is
video on the screen
OSD board is not properly connected with
stop
main control board or the photoelectric
switch is broken
Pan interrupt is not in due position
The system is checking the data again
Fault occurs when the dome device is in tilt
movement. It may be caused by obstacle of
camera of other object, which lead to early
tilt movement
Wrong setting
Improper connection of control cable
Overload or too long distance transmission
Improper contact of control cable
slip ring is damage
RS-485
protective
broken
System failure caused by noise interference
of
dome
No transmission auto "call back" function
is set to the dome device
Something wrong with the setting or wiring
Check if the power cable is
connected to power of AC24V
Change the power PCB
Change slip ring
Change main control board
Switch on the character monitor
according to the menu instruction,
Replace a FFC cable or a camera
CALL up 90 preset position Open
Change OSD board
Grounding the dome device or shut
off the surrounding big electronic
devices(electric,
generating) equipment, or rotate the
camera
Restart the dome device
Connect the controller and set
correct transmission protocol and
baud rate as well as dome device
address
fix OSD board again, if the problem
still exits, then replace the OSD
board
Adjust the pan interrupt
Check and adjust the mechanical
installation
Set the protocol, baud rate and
address of dome device
Check the circuit
Add driver
Check the circuit
Replace slip ring
discharge
arresters
Change 485 protective discharge
arresters
Restart the dome device
Called this setting
check the setting and wiring again
Solutions
HF,
signal
It is normal event
Remarks
Please
follow
the
above basic system
wiring strictly
About
45
second
after
the
dome
device is power on.
After self-test, the
menu can only be
displayed when there
is image display of
the dome device
Shielded
cable
should be adopted
for video cable
There is character
display in normal
circumstance
Pan interrupt should
be at 2/3 of the
central slot within
photoelectric switch
If
this
happens
frequently,
please
adjust
the
pan
interrupt or check if
the connection is too
tight.
Mostly happen in the
connection