Multi-Level Security Arming - Avital 5103 Installation Manual

Car security
Hide thumbs Also See for 5103:
Table of Contents

Advertisement

Multi-level security arming

Multi-Level Security Arming is a feature that allows the user to select which system
inputs or sensors will be active, or will be bypassed when the system is armed.
(See Table of Zones section of this guide.)
Pressing the arm button again within five seconds of arming the system activates
the Multi-Level Security feature. Each time the arm button is pressed after arming,
a different security level is selected. The different levels of security are selected
as follows:
Pressing
one time: The siren chirps once. The system is armed.
Pressing
a second time within five seconds: The siren chirps twice followed
by a long chirp. Zone Two is now bypassed.
�������
Pressing
a third time within five seconds: The siren chirps three times fol-
lowed by a long chirp. Zone Four is now bypassed.
�������
Pressing
a fourth time within five seconds: The siren chirps four times fol-
lowed by a long chirp. Zones Two and Four are now bypassed.
�������
Pressing
a fifth time within five seconds: The siren chirps five times followed
by a long chirp. All input zones, except the ignition, are now bypassed.
�������
�������
40
© 2009 Directed Electronics. All rights reserved.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents