Carrier 24ABA4 Product Data page 20

Base series 14 air conditioner with puronr refrigerant
Table of Contents

Advertisement

DETAILED COOLING CAPACITIES
EVAPORATOR
AIR
75
Capacity
Total
MBtuh†
CFM
EWB
System
KW**
Total Sens‡
72
70.52 37.08
3.97
67
64.33 45.47
3.92
1750
62
58.81 53.84
3.87
57
57.17 57.17
3.86
72
71.76 38.86
4.07
67
65.49 48.34
4.02
2000
62
60.13 57.72
3.98
57
59.48 59.48
3.97
72
72.67 40.54
4.17
67
66.34 51.06
4.12
2250
62
61.32 61.32
4.08
57
61.37 61.37
4.08
Cooling
Indoor Model
*CAP**6024A**
CAP**6021A**
CNPH*6024A**
CNPV*6024A**
CSPH*6012A**
FV4BNB006
FX4CN(B,F)060
FY4ANB060
CNPH*6024A**
CSPH*6012A**
CAP**6024A**
CNPH*6024A**
CNPV*6024A**
CSPH*6012A**
CAP**6024A**
CNPH*6024A**
CNPV*6024A**
CSPH*6012A**
CAP**6021A**
CNPH*6024A**
CSPH*6012A**
CNPH*6024A**
CSPH*6012A**
CNPH*6024A**
CNPV*6024A**
CSPH*6012A**
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable
practice.
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240- -94. If additional
tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C),
deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW)
per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).
When the required data fall between the published data, interpolation may be performed.
** Total system kW is total of indoor and outdoor unit kilowatts.
CONDENSER ENTERING AIR TEMPERATURES deg F
85
Capacity
Capacity
Total
MBtuh†
MBtuh†
System
KW**
Total Sens‡
Total Sens‡
24ABA460A30 Outdoor Section With CAP**6024A** Indoor Section
67.20 35.81
4.38
63.70 34.48
61.31 44.20
4.33
58.13 42.87
56.12 52.55
4.28
53.31 51.19
55.01 55.01
4.27
52.72 52.72
68.29 37.57
4.48
64.63 36.22
62.33 47.04
4.43
59.00 45.69
57.39 56.32
4.38
54.66 54.66
57.15 57.15
4.38
54.68 54.68
69.08 39.23
4.58
65.29 37.86
63.07 49.75
4.53
59.64 48.38
58.90 58.90
4.49
56.27 56.27
58.90 58.90
4.49
56.27 56.27
Multipliers for determining the performance with other indoor sections.
Capacity
1.00
0.98
0.99
0.99
1.00
1.00
1.01
1.00
0.97
0.98
0.98
0.97
0.97
0.98
0.98
0.98
0.98
0.98
0.93
0.94
0.95
0.94
0.95
0.94
0.94
0.95
95
105
Capacity
Total
Total
MBtuh†
System
System
KW**
KW**
Total Sens‡
4.83
59.99 33.10
5.32
4.78
54.75 41.49
5.27
4.73
50.40 49.71
5.23
4.73
50.25 50.25
5.23
4.93
60.76 34.81
5.43
4.88
55.50 44.28
5.37
4.84
52.02 52.02
5.34
4.84
52.03 52.03
5.34
5.03
61.30 36.43
5.52
4.98
56.04 46.94
5.47
4.95
53.45 53.45
5.45
4.95
53.46 53.46
5.45
Power
1.00
0.98
0.99
0.99
1.00
0.96
1.01
1.03
0.97
0.98
0.94
0.93
0.93
0.94
0.94
0.94
0.94
0.94
0.93
0.94
0.95
0.90
0.91
0.90
0.90
0.91
20
115
125
Capacity
Capacity
Total
MBtuh†
MBtuh†
System
KW**
Total Sens‡
Total Sens‡
55.97 31.62
5.86
51.51 30.01
51.12 40.02
5.82
47.11 38.42
47.55 47.55
5.78
44.50 44.50
47.55 47.55
5.78
44.50 44.50
56.59 33.31
5.96
51.97 31.67
51.73 42.78
5.92
47.58 41.13
49.12 49.12
5.89
45.84 45.84
49.12 49.12
5.89
45.85 45.85
57.00 34.90
6.06
52.25 33.24
52.17 45.40
6.01
47.92 43.68
50.38 50.38
6.00
46.91 46.91
50.38 50.38
6.00
46.92 46.92
Furnace Model
58CV(A,X)110---20
58CV(A,X)110---20
58CV(A,X)135---22
58CV(A,X)135---22
58CV(A,X)135---22
58CV(A,X)135---22
58CV(A,X)155---22
58CV(A,X)155---22
58CV(A,X)155---22
58CV(A,X)155---22
58MVB080---20
58MVB080---20
58MVB080---20
58MVB100---20
58MVB100---20
58MVB120---20
58MVB120---20
58MVB120---20
Total
System
KW**
6.45
6.40
6.38
6.38
6.55
6.50
6.48
6.48
6.64
6.60
6.59
6.59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents