Instructions for use of attachments: Desktop Chargers 4-814/4-816
Version: 28.04.2008
1. Main switch/pilot lamp <=> Switch is alight when the charger is ON
2. Charge indicator lamp
<=> Glows steady red when a depleted RECHARGEABLE BATTERY 22/4415-00; 22/4416-00 is being charged
2. Charge indicator lamp
<=> Glows green when RECHARGEABLE BATTERY 22/4415-00; 22/4416-00 is fully charged
3. Charging compartment <=> For inserting the RECHARGEABLE BATTERY 22/4415-00; 22/4416-00 in the direction indicated by the arrow
4. Battery
Preparing for use:
Step 1. Plug in power plug at the socket; switch on at main switch (1); triple-function lamp (2) glows red ( see description in Step 3).
Step 2. Insert RECHARGEABLE BATTERY 22/4415-00; 22/4416-00 (4) into the charging compartment (3) in the direction of the arrow.
Step 3. The charge indicator lamp (2) must first flash red for 20 seconds if the BATTERY 22/4415-00; 22/4416-00 is depleted. After approx.
20 seconds, it glows steady red to indicate that the battery is being charged. When the battery is fully charged, the lamp changes
to green. (4) The charging time for a depleted BATTERY 22/4415-00; 22/4416-00 (4) is approx. 60 minutes. The lamp glows green to indicate
when charging is complete. During charging, the Charger 22/4413-00, 22/4414-00 or 22/4411-00, 22/4412-00 and the BATTERY 22/4415-00;
22/4416-00 warm up, but this does not indicate a fault. As soon as the BATTERY 22/4415-00; 22/4416-00 is fully charged, the lamp glows green (2)
Chargers 22/4413-00, 22/4414-00 or 22/4411-00, 22/4412-00 switch off automatically when the BATTERY 22/4415-00; 22/4416-00 is fully charged.
This means that you can leave the BATTERY 22/4415-00; 22/4416-00 in the operational Charger 22/4413-00, 22/4414-00 or 22/4411-00, 22/4412-00
for a prolonged period so that it is always charged to full capacity without any risk of overcharging
The BATTERY 22/4415-00; 22/4416-00 should be checked and recharged before use!
Fault:
After inserting BATTERY 22/4415-00; 22/4416-00 (4) in the charging compartment (3), the charge indicator lamp (2) on the Charger 22/4413-00,
22/4414-00 or 22/4411-00, 22/4412-00
fails to light up.

FAULT RECTIFICATION:

Turn the BATTERY 22/4415-00; 22/4416-00 (4) slightly in the charging compartment (3), the charge indicator lamp (2) on the Charger 22/4413-00,
22/4414-00 or 22/4411-00, 22/4412-00
fails to light up.

NOTE AND WARNING:

if there is a power fialure, neither of the pilot lamps (1) amd (2) will glow.
Chargers 22/4413-00, 22/4414-00 or 22/4411-00, 22/4412-00 and BATTERIES 22/4415-00; 22/4416-00 are not medical devices, and therefore
should only be used in closed rooms outside the operating theatre. Only use in rooms that are free of dust and moisture.
IMPORTANT: SAFETY INSTRUCTION!
Only store in the original packaging, in a dry, closed room. Never sterilise the BATTERY 4-809/4-810 or the Charger
22/4413-00, 22/4414-00 or 22/4411-00, 22/4412-00. Only use compatible BATTERIES 22/4415-00; 22/4416-00 from LEIBINGER GmbH&Co.KG.
Combination with other makes is forbidden. Do not immerse Charger 22/4413-00, 22/4414-00 or 22/4411-00, 22/4412-00 or
BATTERY 22/4415-00; 22/4416-00 in liquid.