OPTI-UPS Power PS500C User Manual

Power series
Hide thumbs Also See for Power PS500C:

Advertisement

Quick Links

User Guide

Power Series
Models PS500C, PS700C

Advertisement

Table of Contents
loading

Summary of Contents for OPTI-UPS Power PS500C

  • Page 1: User Guide

    User Guide Power Series Models PS500C, PS700C...
  • Page 2: Table Of Contents

    Important Safety Instructions Table of contents IMPORTANT SAFETY INSTRUCTIONS Important Safety Instructions ..............I Introduction ....................III SAVE THESE INSTRUCTIONS 1. Presentation ....................1 ¡ ´ 2. Installation ....................4 CAUTION (UPS Having Internal Batteries): Risk of electric shock - Hazardous live parts inside this unit are energized from the battery supply even when the input AC 3.
  • Page 3: Introduction

    Introduction 1. Presentation Front Panel SAVE THESE INSTRUCTIONS Please read and save this manual! Thank you for selecting this uninterruptible power system (UPS). It provides you with a perfect protection for connected equipment. The manual is a guide to install and use the UPS. It includes important safety instructions for operation and correct installation of the UPS.
  • Page 4 UPS OUTLETS PS500C/700C 110/120V When utility power is normal, the UPS outlets are powered by utility power without AVR function. Any higher or lower utility power would be rectified by AVR function. When utility power is fail, the UPS outlets are powered from battery.
  • Page 5: Installation

    2. Installation 3. Operation 3.1 Switch on: Inspect the UPS upon receipt. The packaging is recyclable; keep it for reuse or be disposed of While utility input is connected to the UPS, press the "ON/TEST" button and keep pressing properly. over than 2 seconds.
  • Page 6: Alarm

    This is normally done to preserve battery capacity after the graceful shutdown of protected 5. Software installation and Interface Port servers. The line LED (Green) will flash every 12 seconds to indicate the shutdown mode. 5.1 Power Monitoring Software Note: The “Green mode” of UPS can be set by SENTINEL. The SENTINEL series software (or other power monitoring software) is applied standard RS-232 interface to perform monitoring functions, and then provides an orderly shutdown of 3.7 Cold start:...
  • Page 7 5.4 The characteristics of software SENTINEL 2. A windows labeled Welcome appears, please read and follow instruction written in the The communication port on the back of the UPS may be connected to host computer. widow and click “Next”. (see Fig 5.3) Through utilizing SENTINEL software the computer is allowed monitor the status of the UPS and control the operation of the UPS in some cases.
  • Page 8: Maintenance And Storage

    (+86 to +113 ¢ K ), charge the UPS‘s battery every 3 months. Fig. 5.7 SENTINEL software can be free download from http:// www.opti-ups .com 6. Maintenance and storage 6.1 Maintenance 6.1.1. Keep the unit clean and vacuum the ventilation intake periodically.
  • Page 9: Appendix A Troubleshooting

    Appendix A Troubleshooting Appendix B Specifications Model PS500C PS700C PROBLEM POSSIBLE CAUSE Solutions Capacity 500VA/300W 700VA/420W Input power source mistake Check out the power source Input Voltage 110V, 120V/ 220V, 230V, 240V Time of pressing the button Keep pressing the “ON/TEST”...

This manual is also suitable for:

Power ps700c

Table of Contents