Page 1
User Guide Power Series Models PS1000B, PS1500B, PS2200B, PS3000B PS1000B-RM, PS1500B-RM, PS2200B-RM, PS3000B-RM...
Page 3
Copyright OPTI International Corporation, 1997. All rights reserved. OPTI-UPS and OPTI-SAFE Xtreme are trademarks of OPTI-UPS Corporation For your records The serial number of your UPS is on the rear panel. You should note the serial number in the space provided below. Retain this booklet as a permanent record of your purchase to aid in identification in the event of theft or loss.
Page 4
LIMITED WARRANTY What the warranty covers: We warrant this product to be free from defects in material and workmanship during the warranty period. If a product proves to be defective in material or workmanship during the warranty period, we will at our sole option repair or replace the product with a like product.
Page 5
Limitation of implied warranties: THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION CONTAINED HEREIN INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Exclusion of damages: OUR LIABILITY IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE PRODUCT.
Page 6
EFFECTIVE October 1, 1997 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS. KEEP THIS MANUAL HANDY FOR REFERENCE. • CAUTION: A BATTERY CAN PRESENT A RISK OF ELECTRICAL SHOCK, BURNS FROM HIGH SHORT-CIRCUIT CURRENT, FIRE OR EXPLOSION FROM VENTED GASES.
Page 7
CAUTION: CONTAINS VOLTAGES WHICH POTENTIALLY HAZARDOUS. REPAIRS SHOULD PERFORMED QUALIFIED SERVICE PERSONNEL. THE UPS HAS ITS OWN INTERNAL ENERGY SOURCE (BATTERY). THE OUTPUT RECEPTACLES MAY BE ALIVE EVEN WHEN THE UPS IS NOT CONNECTED TO AN AC SUPPLY. Safe and continuous operation of the UPS depends partially on the care taken by users.
Page 8
FEDERAL COMMUNICATIONS COMMISSION (FCC) WARNING: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
PS1000B/ PS1500B/ PS2200B/ PS3000 TABLE OF CONTENTS INTRODUCTION Overview Sinewave Output Smart Buck and Boost Line Conditioning User Replaceable Battery Design Advanced Interface to Communicate with Computer User Configurable Settings Data-Line Surge Protection UPS CONTROLS External Views Front Panel Rear Panel On Button Off Button Select Button...
PS1000B / PS1500B/ PS2200B / PS3000B INTRODUCTION 1.1 Overview These models are advanced line-interactive true sinewave uninterruptible power systems (UPS) designed to prevent spikes, surges, sags, transients and blackouts from reaching your sensitive equipment. Your equipment may include such items as computers and computerized instruments to telecommunication systems.
PS1000B/ PS1500B/ PS2200B/ PS3000 1.4 User Replaceable Battery Design The battery is the most critical part in a UPS. The average lifetime of a battery is between 2 and 3 years. The special user-replaceable battery design of this UPS provides significant savings and gives the UPS an almost unlimited life. You can replace the battery very easily, and without turning off your UPS or the equipment it is protecting.
PS1000B / PS1500B/ PS2200B / PS3000B MODEL: PS1000B-RM, PS1500B-RM 100V/110V/120V PS2200B-RM, PS3000B-RM 220V/230V/240V 2.2 On Button 1. When the UPS is off and AC power is present, press the On button for 1~2 seconds to turn on the UPS. UPS can be turned on even when AC power is not present. 2.
PS1000B/ PS1500B/ PS2200B/ PS3000 2.4 Select Button The relevant value appears on the upper screen. There are several parameters can be selected Output voltage display Input voltage display Input frequency Temperature inside the UPS Output frequency Load level percentage 2.5 Load Percentage Bar Graph The LCD display on the front panel shows the current load percentage.
PS1000B / PS1500B/ PS2200B / PS3000B 2.9 Communication Port The communication port on the rear panel of the UPS allows for connection to a host computer. When used with software communication software you will have access to important operating information. From your computer screen, you can monitor input/output voltage, AC frequency, battery voltage, etc., and analyze power problems.
PS1000B/ PS1500B/ PS2200B/ PS3000 3. INSTALLATION AND OPERATION Before installation, please read and understand the following instructions: 3.1 Unpacking and Inspection Examine the packing carton for damage. Notify the carrier immediately if damage is observed. 3.2 Placement This unit is intended for indoor use only. Although your UPS is very rugged, its internal components are not sealed from the environment.
PS1000B / PS1500B/ PS2200B / PS3000B Computer Co ViewSonic G810 Pentium Pro 200MHz 120V 2.7A 120V 2.0A 50 / 60 Hz 50/60 Hz SN: Q771515388 SN: 123456 Multiply the voltage and current of each piece of equipment (VA requirements); for example, 120V x 2.7A = 324VA, 120V x 2.0A = 240VA. Add up the VA requirements for each device;...
Page 19
PS1000B/ PS1500B/ PS2200B/ PS3000 DO NOT PLUG LASER PRINTERS INTO THE UPS BECAUSE THEY TYPICALLY DRAW TOO MUCH POWER...
PS1000B / PS1500B/ PS2200B / PS3000B 3.6 Operation and Functional Test Plug in the AC input cord to the rear panel and turn on the UPS by pressing the “On/Off” switch for 3 seconds. The UPS will beep and the front panel Normal Mode LED will light.
PS1000B/ PS1500B/ PS2200B/ PS3000 4.2 Mechanical Specifications: Product Name Dimensions Weight (Kg) W × L × H (mm) Shipping PS1000B 140 x 445 x 200 170 x 450 x 215 PS1500B 170 x 450 x 215 PS2200B 170 x 450 x 215 26.8 29.3 PS3000B...
PS1000B / PS1500B/ PS2200B / PS3000B 5. TROUBLESHOOTING The TROUBLESHOOTING CHART below covers most of the difficulties that you may encounter under normal working conditions. If the UPS fails to operate properly, please review the following steps before calling the repair center: 1.
PS1000B/ PS1500B/ PS2200B/ PS3000 6.USER REPLACEABLE BATTERY The Batteries inside this UPS should last from between 2 to 3 years. If you suspect that the batteries are weak, allow the UPS to charge the batteries for at least six hours and then test the backup time. If the UPS still does not provide adequate backup time, follow the procedures below to replace the batteries.
PS1000B / PS1500B/ PS2200B / PS3000B 6.2 Battery Replacement Procedure PS-1000B Changing the batteries in your UPS is a safe and easy procedure. Since the battery is isolated from the AC input you may leave your UPS and computer or other equipment on during the following procedure.
Page 27
PS1000B/ PS1500B/ PS2200B/ PS3000 PS-1500B Changing the batteries in your UPS is a safe and easy procedure. Since the battery is isolated from the AC input you may leave your UPS and computer or other equipment on during the following procedure. Please note that if you choose to leave the UPS on when the battery is removed, it will not be able to power your equipment if a power failure occurs.
Page 28
PS1000B / PS1500B/ PS2200B / PS3000B PS1000B-RM/PS1500B-RM/ PS2200B-RM/ PS3000B-RM Changing the batteries in your UPS is a safe and easy procedure. Since the battery is isolated from the AC input you may leave your UPS and computer or other equipment on during the following procedure. Please note that if you choose to leave the UPS on when the battery is removed, it will not be able to power your equipment if a power failure occurs.
Need help?
Do you have a question about the Power Series and is the answer not in the manual?
Questions and answers