• Magne-Traction (in command mode) Table of contents Transformer operations Running your Lionel SD60-M with a Lionel transformer Locking your SD60-M into a single operational state Using your SD60-M’s Electrocoupler Plus couplers Your SD60-M’s Railsounds system—the basics Experiencing the range of your SD60-M’s Railsounds system Notes on Railsounds Installing the Lionel no.
WITH DIRECT CURRENT sitive electronic components may occur. • When you first power up your track, the SD60-M will wait between 3 and 8 seconds as it “listens” for digital language from the TrainMaster Command Base (available separately). When it’s determined that it’s on a conventional (nonCommand) railroad, the SD60-M’s headlight will illuminate and...
Transformer operations Locking your SD60-M into a single operational state without stopping. Set the reverse unit o select a single operational state for control switch to PROGRAM/LOCK. your Lionel SD60-M (example: for- The SD60-M is now “locked” into your ward only), you can deactivate the chosen direction.
Slide open the (horn and bell access panel as remain unaf- Install a 9-volt alkaline battery in your SD60-M . shown in the fected), slide illustration. Connect the 9-volt alkaline the Railsounds switch, located under- battery to the battery clip, and place...
Transformer operations Experiencing the range of your SD60-M’s Railsounds system Now, decrease track voltage to the ith Railsounds, you experience desired speed level, press DIR on your the sounds of real railroading CAB-1 remote or transformer, and like never before. Simply put, it’s the...
(for bell) (for horn) The no. 610-5906-001 sound activation button (available separately) works with any Lionel AC transformer except no. 6-4690 Type MW. Note! Transformers made by other manufacturers may not be compatible with Railsounds.
• All Command-equipped Lionels come factory-programmed with an ID# of “1.” To change your SD60-M’s ID#, see page 12. Move ‘em out! • Throttle up or press any command button on CAB-1. Your SD60-M will respond to your every command. Read on. The fun is just beginning!
Command-equipped SD60-M Example address Locomotive #1 comes factory-programmed with an ID# of “1.” To get your SD60-M in PowerMasters set to CMD or traditional action, set PowerMasters to CMD or power supplies ON FULL set all power supplies on full. Press ENG and “1”...
TARTUP SEQUENCE COMMENCES Lowers the volume of Rail- Turns strobe light off. sounds. S OUND VOLUME DECREASES Activates the Railsounds shut- Turns strobe light on. down sequence. Just like the real thing, your SD60-M’s RPMs must be at idle...
“stall” voltage. Get mand environment gives you a bonus your locomotive moving, then press Railsounds effect—the ultrarealistic SET; the SD60-M will stop. Turn the sound of squealing brakes. throttle clockwise to get the locomotive moving, then decrease speed until the SOUND QUALITY locomotive just stops.
SD60-M’s cab number. Command Base ON Turn the Command Base ON and Place the SD60-M on track place the SD60-M on track. Power up, PowerMasters set to CMD or then set the SD60-M’s reverse unit con- traditional power supplies ON FULL trol switch to PROGRAM/LOCK (see the illustration).
Maintaining and servicing your SD60-M Lubricating your SD60-M grease or oil on the SD60-M’s wheels or elp your Lionel SD60-M lead a your track. long and productive life on your You’ll know your SD60-M requires railroad by maintaining it properly.
@@ @@ @@ @@ yy yy 2 cab screws After removing the .050" set screw, place a small amount of Lionel oil (two drops maximum) in the set screw hole. Reinstall the set screw tightly, then back off one-half turn.
Page 15
Press Aux2 to make sure headlamp was not accidently turned off, Note! before replacing bulb Your Lionel SD60-M is equipped with a roof mounted flashing strobe light, this small bulb (Lionel part no. 10-8803-009) is located inside the cab. During the course of normal operation it may require Note! replacement.
Lionel while at Lionel. You may choose to have your and carries a limited warranty to support product repaired by one of our authorized continued reliable operation. If service is...