LG Art Cool Mirror Inverter Engineering Manual page 11

Art cool mirror inverter wall mounted
Table of Contents

Advertisement

Table 2: Unit General Data
Type
System (Model)
nominal Cooling Capacity (Btu/h)
Cooling Power Input
(kW)
1
nominal Heating Capacity (Btu/h)
Heating Power Input
(kW)
1
Cooling CoP
EER
SEER
HSPF
Power Supply (V / Hz / Ø)
ODU Operating Range
Cooling (°F DB)
Heating (°F WB)
IDU Operating Range
Cooling (°F WB)
Heating (°F DB)
Indoor Temperature Setting Range
Cooling (°F)
Heating (°F)
Unit Data
Refrigerant Type
2
Refrigerant Control
IDU Sound Pressure
dB(A) (H/M/L)
3
oDU Sound Pressure dB(A)
Unit Weight (lbs)
Indoor Unit (net/Shipping)
outdoor Unit (net/Shipping)
Power/Communication Cable
4
Fan
Indoor Type (Qty)
outdoor Type (Qty)
Motor/Drive
Airflow Rate
Indoor - H/M/L (CFM)
outdoor - Max (CFM)
EEV: Electronic Expansion Valve IDU: Indoor Unit oDU: outdoor Unit
Power wiring is field supplied and must comply with the applicable local and national codes.
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
LA090HSV2 (LAn090HSV2/LAU090HSV2)
(no. x AWG)
Due to our policy of continuous product innovation, some specifications may change without notification.
Art Cool Mirror Inverter Specifications
Art Cool Mirror
9,000
0.68
10,800
0.70
3.90
13.3
20
11
208-230/60/1
14-118
5-75
64-90
60-86
65-86
61-86
R410A
EEV
38/33/24
45
25/30
78/82
4 x 18
Cross Flow (1)
Propeller (1)
Brushless Digitally Controlled/Direct
335/272/212
1,165
Power Input is rated at high speed.
1
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy
2
R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608
of CAA.
Sound Pressure levels are tested in an anechoic chamber under ISo Standard 1996.
3
All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must
4
comply with applicable and national code.
gEnEral data
LA120HSV2 (LAn120HSV2/LAU120HSV2)
11,200
0.90
13,300
1.00
3.66
12.5
39/33/24
353/272/212
ProduCT dATA | 11