11. Install the adapter on the PRV and tighten using
two wrenches. Use the mark made earlier on the
adapter to orient the PRV to the desired direction
in relation to the water connections on the header.
12. Wrap the threads of the adapter with a suitable
teflon thread tape.
13. Reinstall the adapter, with the PRV, into the
plastic threaded hole and tighten it until the mark
on the adapter is once again facing the same
direction as the water connections on the header.
caution
Do not use any pipe compound or pipe dope on
the threads of the adapter or any part that comes in
contact with the plastic headers. These compounds
may damage the header over a period of time.
attention
N'utilisez ni pâte à joint ni pâte lubrifiante sur le
filetage du raccord intermédiaire ou sur toute pièce
qui entre en contact avec le tuyau collecteur. Ces
produits risquent d'endommager le tuyau après un
certain temps.
caution
In order to prevent property damage, do not over-
tighten. Overtightening may crack the header.
attention
Afin d'empêcher des dégâts matériels, ne serrez
pas trop. Le serrage excessif peut provoquer des
fissures dans la tête.
DO NOT TIGHTEN WITH A WRENCH.
Overtightening may crack the header. Route the
discharge piping so that discharge from the pipe does
not endanger anyone near the heater. Refer to your
local installation codes for more detailed information.
The valve setting should be at or below the maximum
working pressure of any component in the filter
system. The maximum working pressure of the Legacy
Model LRZ electronic heater is 75 psig.
5.7
auxiliary components,
chlorinators, ozone Generators,
and Sanitizing chemicals
The Legacy Model LRZ electronic heater is
manufactured with materials that are not compatible
with high concentrations of ozone, chlorine, bromine,
or other sanitizing chemicals. Heater damage caused
by excessive chemicals or improper ozonization is not
covered by the Zodiac Pool Systems, Inc., warranty.
Be sure to adhere to the following:
When ozone is injected upstream of the heater,
install an offgas mixing chamber, or an ozone
bypass system between the heater and the ozone
injector to prevent ozone and air from entering
the heater.
Jandy ® Legacy™ Model LRZE Pool/Spa Heater by Zodiac ®
|
ENGLISH
When chemical feeders are used, plumb the
feeder downstream of the heater and install an
in-line check valve between the heater and the
feeder. A minimum of 18" (46 cm) is required
between the heater and the check valve.
Wire any electrical chemical feeder so that it
cannot operate unless the filter pump is running.
If the feeder has an independent clock control,
synchronize it with the filter clock.
Never deposit chemicals directly in the pool
skimmer.