Ambient Weather WS-HT350 User Manual

Ambient Weather WS-HT350 User Manual

Fast response air thermo-hygrometer with wet bulb, dew point meter

Advertisement

Quick Links

Ambient Weather WS-HT350 Fast Response Air
Thermo-Hygrometer with Wet Bulb, Dew Point Meter User

Table of Contents

1.
Introduction ..................................................................................................................................... 1
2.
Getting Started ................................................................................................................................ 1
2.1 Recommend Tools ......................................................................................................................... 1
2.2
Meter Operation ..................................................................................................................... 1
3.
Display Console Layout .................................................................................................................. 2
4.1 Display Layout .............................................................................................................................. 2
4.2
ON / OFF ................................................................................................................................ 2
4.3
Min and Max Mode ................................................................................................................ 3
4.4
°F, °C, Dew Point, Wet Bulb Mode ........................................................................................ 3
4.5
Backlight and Hold ................................................................................................................. 3
5.
Glossary of Terms ........................................................................................................................... 3
6.
Specifications .................................................................................................................................. 4
6.1
Measurement Specifications ................................................................................................... 4
6.2
Other Specifications and Features .......................................................................................... 4
7.
Troubleshooting Guide .................................................................................................................... 4
8.
Liability Disclaimer ........................................................................................................................ 4
9.
FCC Statement ................................................................................................................................ 5
10.
Warranty Information ................................................................................................................. 5

1. Introduction

Thank you for your purchase of the Ambient Weather WS-HT350 Fast Response Thermo-Hygrometer
with Wet Bulb, Dew Point Meter. The following user guide provides step by step instructions for,
operation and troubleshooting. To download the latest manual and additional troubleshooting tips,
please visit:

2. Getting Started

The WS-HT350 consists of the meter, carrying case and 1 x 9V battery.

2.1 Recommend Tools

Philips screwdriver (precision) for battery compartment

2.2 Meter Operation

Remove the battery door on the back of the display with a precision screwdriver. Insert the 9V battery
(included) into the battery connector and replace the battery door.
Press the Red Power On button on the front of the meter until the display begins updating. The
Version 1.0
©Copyright 2011, Ambient LLC. All Rights Reserved.
Manual
http://ambientweather.wikispaces.com/wsht350
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WS-HT350 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ambient Weather WS-HT350

  • Page 1 Warranty Information ......................... 5 1. Introduction Thank you for your purchase of the Ambient Weather WS-HT350 Fast Response Thermo-Hygrometer with Wet Bulb, Dew Point Meter. The following user guide provides step by step instructions for, operation and troubleshooting. To download the latest manual and additional troubleshooting tips, please visit: http://ambientweather.wikispaces.com/wsht350...
  • Page 2: Display Console Layout

    meter is now ready for use. Important Note: This is an air temperature probe only. DO NOT SUBMERSE IN LIQUID. DO NOT PLACE IN OPEN FLAME. This will damage the sensor board and void the warranty. Do not use in extreme cold or extreme hot temperatures (such as an oven or non-ambient environment such as carbon dioxide gas).
  • Page 3: Min And Max Mode

    again. 4.3 Min and Max Mode Press the MAX / MIN button once to enter the Min and Max Mode. The maximum humidity and temperature values will be shown since the last reset. The MAX icon will be displayed at the top of the display.
  • Page 4: Specifications

    6. Specifications 6.1 Measurement Specifications The following table provides specifications for the measured parameters. Measurement Range Accuracy Resolution Temperature -22 to 199 °F ± 0.9 °F 0.01 °F / °C (-30 to 100 °C) (± 0.5 °C) at 25°C ± 1.5 °F (±...
  • Page 5: Fcc Statement

    wild country and/or in unauthorized grounds strongly damages the environment. Reading the “User manual” is highly recommended. The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place. The specifications of this product may change without prior notice.

Table of Contents