Mira Sport Thermostatic 9.0 Installation & User Manual page 9

Electric shower
Table of Contents

Advertisement

Plumbing (checklist in detail)
1.
The appliance is designed to operate with a minimum maintained inlet pressure
of 70 kPa (0.7 bar), 100 kPa (1.0 bar) recommended, up to a maximum static
inlet pressure of 1000 kPa (10 bar).
2.
When installed in very hard water areas (above 200 ppm temporary hardness)
your installer may advise the installation of a water treatment device, to reduce
the effects of limescale formation. Your local water company will be able to
advise the hardness of water in your area.
3.
It is recommended that a non-restrictive (free flowing) isolating valve is fitted
as part of the cold water supply pipe to allow the complete maintenance of the
Mira Sport Thermostatic. Do not use a valve with a loose washer plate (jumper)
as this can lead to a build up of static pressures.
4.
The appliance is suitable only for installation within the shower area. It is fitted
with a pressure relief device and must be positioned over a water catchment
area with the controls at a convenient height for all users.
5.
The appliance must be fitted onto a finished flat and even wall surface (this
wall surface should be tiled or waterproofed). Do not fit the appliance to the
wall and tile up to the case. For safety requirements, an air gap must be left
behind the appliance.
6.
Avoid layouts where the shower hose will be sharply kinked. This may reduce
the life of the hose.
7.
A Soap Dish/Hose Retaining Ring is supplied to prevent the handset from
dropping below the spill-over level of the bath or shower, which could lead to
contamination from back-siphoning. The supplied Hose Retaining Ring should
meet the great majority of user requirements for shower installations with
flexible outlet fittings. However, there will be occasions when it will not provide
a suitable solution. In these instances an outlet double checkvalve, e.g. a Mira
DCV-H, must be fitted. This will increase the required supply pressure typically
by 10 kPa (0.1 bar) refer to section: 'Accessories'.
8.
Supply pipework must be flushed to clear debris before connecting to the
appliance.
9.
To avoid damage to the case when soldered fittings are used, pre-solder the
pipework and fittings before connecting them to the inlet connector assembly.
Refrain from applying excessive force when making any connections. Always
provide mechanical support when making the plumbing connections.
10. The appliance is fitted with a brass inlet compression assembly for connecting
to a 15 mm supply pipe from the top, bottom or back. Double checkvalves,
fitted in the inlet supply to the appliance, cause a pressure build-up, which
could exceed the maximum static inlet pressure and damage the appliance.
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sport thermostatic 9.8

Table of Contents