Battery - Husqvarna PZ5426 FX / 966060901 Operator's Manual

Husqvarna lawn mower user manual
Hide thumbs Also See for PZ5426 FX / 966060901:
Table of Contents

Advertisement

Battery

The mower is equipped with a maintenance free
battery and does not need servicing. However,
periodic charging of the battery with an automotive
type battery charger will extend its life.
Keep battery and terminals clean.
Keep battery bolts tight.
See charge for charging times.
WARNING!
Always wear eye protection when
around batteries.
Battery Removal
Corrosion and dirt on the battery and terminals can
cause the battery to "leak" power.
1.
Lift the seat and rotate fully forward until
supported by the seat rod.
2.
Loosen the two wingnuts attached to the side
"J" bolts just enough that the battery mount
bracket slides down off the battery.
3.
Using two ½" wrenches disconnect BLACK
battery cable then RED battery cable.
4.
Carefully remove the battery from the mower.
For cleaning
5.
Rinse the battery with plain water and dry.
6.
Clean terminals and battery cable ends with
wire brush until shiny.
For replacing
7.
Install new battery with terminals in the same
position as the old battery.
8.
Connect RED battery cable first to positive (+)
battery terminal.
9.
Connect BLACK grounding cable to negative (-)
battery terminal.
10.
Slide mount bracket back up over battery and
retighten wingnuts.
11.
Lower seat.
42
maINTeNaNCe
STANDARD
BATTERY
12.6V
12.4V
12.2V
12.0V
11.8V
IMPORTANT INFORMATION
Do not attempt to open or remove caps or
covers. Adding or checking level of electrolyte
is not necessary.
Always use two wrenches for the terminal
screws.
1. Mount bracket
2. Battery bracket
Battery cleaning and installation
STATE
APPRoXIMATE BATTERY CHARGING TIME*
To FULL CHARGE AT 80
oF
CHARGE
50 Amps
100%
- FULL CHARGE -
75%
20 min.
50%
45 min.
25%
65 min.
0%
85 min.
*Charging time depends on battery capacity,
condition, age, temperature and efficiency of charger
WARNING!
Do not short battery terminals by
allowing a wrench or any other
object to contact both terminals at
the same time. Before connecting
battery, remove metal bracelets,
wristwatch bands, rings, etc.
Positive terminal must be connected
first to prevent sparks from
accidental grounding.
1
2
F / 27
C
o
o
Maximum Rate at:
30 Amps
20 Amps
10 Amps
35 min.
48 min.
90 min.
75 min.
95 min.
180 min.
115 min.
145 min.
280 min.
150 min.
195 min.
370 min.
8065-020

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents