Specifications

Temperature ranges
Heat: 45 – 79°F (7 – 26°C)
Cool: 58 – 92°F (14 – 33°C)
Display: 40 – 100°F (5 – 37°C)
Sensitivity: +/- 1°F (0.5°C)
Equipment Interface Operating: -40o to 160oF (-40o to 70oC)
Thermostat Operating: 32o to 130oF (0o to 55oC)
Humidity Range
Humidify: 20 to 50% R.H
Dehumidify: 30 to 60% R.H
Display: 0 - 90% R.H
Sensitivity: +/- 2% R.H.
Operating: 5 – 95% R.H non-condensing
Dimensions
Thermostat: 5.5"W x 3.25"H x 1"D (139.5mm H x 82.5mm
W x 25mm D)
Equipment Interface: 4.6"W x 10"H x 1.3"D (118mm W x
254mm H x 32mm D)
Power
AC Transformer - 24 VAC - 3VA Minimum (not included)
Battery – CR2032 – 3V lithium coin cell (included),
Power Adaptor - #EB-PS-01 - 120V 50/60Hz to 12V DC 1A
(not included)
5
Getting Started
IC: 7981A-EBSTAT
Wiring Specifications
Refer to this table to determine maximum wire lengths allowed:
Smart Thermostat to Equipment Interface
18 AWG
20 AWG
1250ft/380m
790ft/240m
Equipment Interface to heating/air equipment
18 AWG
20 AWG
128ft/39m
80ft/24m
Terminal Description and Electrical Ratings
Terminal
Description
Y
1st stage cooling
W (O/B)
1st stage heating
(or changeover)
G
Fan
W2(AUX)
2nd stage heating
(or 1st auxiliary heat)
R/H
Heat transformer return
R/C
Cool transformer return
ACC1
1st accessory relay
ACC1r
1st accessory relay return
ACC2
2nd accessory relay
ACC2r
2nd accessory relay return
ACC3
3rd accessory relay
ACC3r
3rd accessory relay return
IN1 +
Input 1 +
IN1-
Input 1 -
IN2+
Input 2 +
IN2-
Input 2-
+12v
12V DC power to Thermostat
GND
GND to Thermostat
D+
Data + communication line
D-
Data – communication line
22 AWG
500ft/150m
22 AWG
50ft/15m
Voltage
Current max
30V AC
3A
30V AC
3A
30V AC
3A
30V AC
3A
30V AC
3A
30V AC
3A
30V AC
3A
30V AC
3A
30V AC
3A
30V AC
3A
30V AC
3A
30V AC
3A
Dry contact only
Dry contact only
Dry contact only
Dry contact only
Dry contact only
Dry contact only
Dry contact only
Dry contact only
8-14V DC
600mA
-
-
-
-
-
-