Download Print this page

Quick Install; Quick Install Menu - Bosch Divar 700 Series Quick Install

Digital hybrid recorder digital network recorder
Hide thumbs Also See for Divar 700 Series:

Advertisement

Divar 700 Series

Quick install

To get the unit quickly operational, make the connections
described below and then enter the relevant data in the Quick
install menu.
Connections
1.
For hybrid versions, connect the cameras to the BNC
Video in connectors (automatically terminated).
2.
Connect monitor A to the CVBS, Y/C, or VGA (supporting
1280x1024) output MON A.
3.
Connect the USB mouse to a USB port.
4.
Connect monitor B to the CVBS, Y/C, or VGA (supporting
1024x768) output MON B*.
5.
Connect up to 16 audio signals to the RCA Audio in
connectors*.
6.
Connect the RCA Audio out connector(s) to a monitor or
an audio amplifier.
7.
Connect up to 16 inputs to the Alarm I/O via the 25-pin
connector board.
8.
Connect up to 4 alarm outputs to the Alarm I/O via the
25-pin connector board.
9.
Connect the malfunction output (MAL OUT) via the
screw terminal adapter.
10.
Connect an Intuikey keyboard to the KBD in socket and
connect the terminator (supplied with the keyboard) to
the KBD out socket.
11.
Connect a Bosch pan/tilt/zoom control unit to the
Biphase port (via the 15-pole D-type connector board).
12.
Connect a third-party pan/tilt/zoom control unit to the
RS485 port (via the screw terminal adapter).
13.
Connect to your network via the Ethernet port. (Some
versions have a Secondary Ethernet port which can be
used as a separate network connection.)
14.
Connect your IP cameras to the network.
Switch on all connected equipment.
15.
Connect the power cord to the unit.
First-time use
The Quick install menu opens the first time the unit is used. Fill
in the basic settings in the tabs to get the unit operational. The
unit begins recording automatically when the Quick install
menu is closed.
Navigating
Use the USB mouse or the following front panel keys:
Bosch Security Systems
Use the enter
button to select a submenu or
item.
Use the arrow
move through a menu or list.
Use the escape
button to go back or to
switch off the menu.

Quick install menu

The Quick install menu contains four tabs: International,
Network, Schedule, and Recording. Navigate through these
tabs using Back and Next. Click Undo to cancel changes made
in the active tab. Click Close to exit the Quick install menu.
Changing Quick install settings overwrites customized settings.
International
Language — Select the language for the menu from the list.
Time zone — Select a time zone from the list.
Time format — Select either a 12 or a 24 hour clock format.
Time format — Fill in the current time.
Date format — Select a date format with month (MM), day
(DD), or year (YYYY) first.
Date — Fill in the current date.
Schedule
The currently active weekly schedule is shown. Each color
represents an available profile:
Click Overwrite to start making changes.
Select on which day the week should start and end.
Select when the day begins and ends on weekdays.
Select when the day begins and ends on weekends.
The display is automatically updated when settings are
changed.
Recording
Set the Normal recording Resolution, Quality, and Frame rate
for each profile in the table. Set the Alarm and Motion
recording Resolution, Quality, and Frame rate. These settings
are set for all profiles. If advanced settings were previously
made, click Overwrite to replace them with Quick install
settings.
Network
Fill in the settings that control the behavior of the unit with
respect to a network.
buttons to
DVR name — Enter a unique DVR name to be used in the
network.
DHCP — Enable DHCP to have IP address, Subnet mask, and
Default gateway assigned automatically by the DHCP server of
the network. The actual values are displayed.
IP address — Fill in the IP address when DHCP is not
enabled.
Subnet mask — Fill in the Subnet mask when DHCP is not
enabled.
Default gateway — Fill in the Default gateway when DHCP is
not enabled.
Auto DNS address — Enable to have the DNS server IP
address assigned automatically. The assigned address is
displayed.
DNS server — Fill in the DNS server address when Auto DNS
address is not enabled.
MAC address — The MAC address is read only.
Connection — Shows current network speed of the primary
Ethernet connection.
Remote streaming limit — Enter a value between 0 and
1000 Mbps to restrict the network bandwidth available for
streaming audio and video to all BVC workstations combined.
Quick install | en
3
F.01U.247.164 v3.4 | 2011.10

Advertisement