Omron BU1002RW Instruction Manual page 53

200-240v
Table of Contents

Advertisement

7
. Using the UPS monitoring software and contact signal
• UPS monitoring software function list
Function
Required options
Auto shutdown (*1)
UPS monitoring (operating status)
UPS monitoring (data)
Pop-up notification
End when OS is inactive (*3)
Schedule operation
UPS setting change
External command execution
Event log save
Software
Data log save
function
Coordinated shutdown (shutdown
of multiple units)
Output receptacle control
Redundant power supply support
Remote UPS management
Mail send
SNMP management
Telnet connection
SYSLOG support
*1) The UPS automatically stops only when the battery is depleted. (Battery Mode continues until the battery is depleted.)
*2) Only the battery capacity can be monitored.
*3) This function is available only for Windows, not for Linux.
[Explanation of software functions]
1 Auto shutdown
2 UPS monitoring (operating
status)
3 UPS monitoring (data)
4 Pop-up notification
5 Shutdown when OS is
inactive
6 Schedule operation
7 UPS setting change
8 External command
execution
9 Event log save
10 Data log save
11 Coordinated shutdown
12 Redundant power supply
support
13 Remote UPS management The UPS can be managed remotely from a computer on the network.
14 Mail send
15 SNMP management
16 Telnet connection
17 SYSLOG support
41
Software title
UPS service
driver
▲ (*2)
The computer can be shut down automatically when a problem occurs with the power supply.
The operating status of the UPS can be monitored (in Commercial Power Mode/Battery Mode).
Monitoring can be performed for input voltage value, connection capacity, battery capacity, etc.
When a problem such as a power failure occurs, a pop-up window that shows the details of the problem can be displayed.
Shutdown can be performed when the computer is in an inactive state. The operating status is retained at shutdown in inactive
state, so operation details are not lost.
Schedule settings can be made for UPS stop/start.
UPS settings (beep ON/OFF, etc.) can be changed. (Items that can be set vary according to the UPS.)
By executing commands at shutdown, items such as application programs can be launched.
Information of events that occur on the UPS (power supply problems, setting changes, occurrences of failure, etc.) are saved as
a log.
Data of input/output voltage value, connection capacity, etc. is periodically saved as a log (the save frequency can be set).
When a problem occurs with the power supply, multiple computers connected to the UPS can coordinate to perform auto
shutdown.
Two or more UPS can be connected to computers equipped with redundant power supply. Shutdown is not performed when a
power supply proble affects only one of the units. Shutdown is performed only when a power supply problem occurs with both
UPS, so the system's operating rate is improved.
When a problem such as a power failure occurs, a notification email describing the problem can be sent to the system
administrator.
UPS management information can be sent to the SNMP manager.
Settings such as shutdown parameters can be made via the Telnet connection.
UPS management information can be recorded in SYSLOG.
● Supported
General applications
(Simple functions, standalone)
Simple
OS standard
Shutdown
UPS service
Software
BUC26
● (*1)
▲ Limited
Unsupported
Network
SNMP management
management
applications
applications
(Advanced functions,
(Advanced functions,
network support)
network support)
SNMP/Web
PowerAct Pro 4.x
card
SNMP/Web
card SC20G

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents