Precautions:
1. After lighting, observe the burner flame. Make sure the burner ports are lit.
2. If the burner flame goes out during operation, immediately turn the gas "OFF". Open lid to let the gas clear for at
least 5 minutes before re-lighting.
3. Before cooking on the grill for the first time and operate the grill for approximately 15 minutes with the lid closed and
the gas turned on "HIGH". This will "heat clean" the internal parts, dissipate odor from the manufacturing process
and painted finish.
4. Clean the grill after each use. DO NOT use abrasive or flammable cleaners. This may damage parts of the grill and
cause a fire.
Confirm that the burner is properly lit and that the flame pattern is as desired (see fig. A, B and C below for the proper
flame patterns). If the flame pattern is other than normal, consult the Troubleshooting on page 16 for corrective action.
FIG. A
Normal: Soft blue flames with yellow
tips between I inch - 2 inches high.
Burner installation and adjustment
Burner ports should face towards
upside.
Flare-ups
"Flare-ups" sometimes occur when food drippings fall onto the hot heat distribution plate or burners and ignite. Some
flaring is normal and desirable as it helps impart the unique flavors associated with grilled foods. Controlling the intensity of
the flare-ups is necessary, however, in order to avoid burned or unevenly cooked foods and to prevent the possibility of
accidental fire.
GSF20JD/GSF20JDS
Instruction Manual
2 in.
1 in.
Observe flame height when lit:
Flame should be a blue/yellow color between 1 to 2 inches high.
0 in.
Out of adjustment: Noisy hard blue
flames – too much air.
1. Release the screw on venturi tube.
2. Adjust the flame by turning the collar
on head of venturi tube from back side
of the grill and do not take apart the
venturi tube.
3. Tighten the screw and make certain it
is secured.
FIG. B
12
FIG. C
Poor combustion: Wavy, yellow
flames- too little air.
1. Overlap 14 mm between
venturi tube and nozzle
when assembling.
2. Keep the center line of
venturi tube and nozzle
on one line.