Husqvarna 230 ACX/220 AC Operator's Manual page 55

Husqvarna auto mower operator's manual
Table of Contents

Advertisement

Test IN (3-2-4)
The Test IN (3-2-4) function is used to test how
Automower finds its way into the charging
station.
When the function is selected the mower will
immediately follow the boundary wire, guide 1 or
guide 2, depending on which one it finds first, in
to the charging station. If there is a passage and
the mower can not run through it, the Corridor
width value is set too high. When Test IN is
activated, the mower runs at the greatest
distance from the wire that the selected corridor
width permits.
The adjacent picture shows how Automower
negotiates a passage when a value of 5 is set for
the Corridor width, but not when a value of 6 is
set.
IMPORTANT INFORMATION
When Test IN (3-2-4) is used, the house icon
on the display will come on and the mower
will remain in the charging station. Press the
Home button to return to operations.
Test OUT (3-2-5)
The Test OUT (3-2-5) function is used to try
different charge exit settings and to find out how
far it is from the charging station to a remote
area.
To test the settings for Follow loop out (3-2-1):
• State the value 100 % for Proportion for the
remote area to be tested. Place Automower in
the charging station and select Test OUT
(3-2-5). The mower will now leave the charging
station directly according to the stated direction
and start mowing after the stated distance.
Reset the Proportion value when testing is
finished.
56 - English
6. MENU FUNCTIONS
Follow loop out
Follow loop in
Corridor width
Test IN
Test OUT
3-2-4
Follow loop out
Follow loop in
Corridor width
Test IN
Test OUT
3-2-4
3012-672

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Automower 230 acxAutomower 220 scAutomower 220 c

Table of Contents