Service Valve Connections; Remote Control Unit Installation Position; Mounting On A Wall - Sanyo KS3082 Installation Instructions Manual

Inverter split system air conditioner
Hide thumbs Also See for KS3082:
Table of Contents

Advertisement

10-018 C3082-3682
2/15/10

Service Valve Connections

a) Temporary connection:
Screw in 3 – 5 turns by hand. (Fig. 60c)
b) To fasten the flare nuts, apply specified torque
as Table 9 and Fig. 60d.
Table 9
Tube Dia.
1/4" (6.35 mm)
21/32" (17 mm)
3/8" (9.52 mm)
7/8" (22 mm)
1/2" (12.70 mm)
1-1/32" (26 mm)
5/8" (15.88 mm)
1-5/32" (29 mm)

7. Remote Control Unit Installation Position

The remote control unit can be operated from either a
non-fixed position or a wall-mounted position.
To ensure that the air conditioner operates correctly, do
not install the remote control unit in the following places:
In direct sunlight
Behind a curtain or other place where it is covered
More than 26' (8 m) away from the air conditioner
In the path of the air conditioner's airstream
Where it may become extremely hot or cold
Where it may be subject to electrical or magnetic
interference
Where there is an obstacle between the remote con-
trol unit and the air conditioner (since a check signal
is sent from the remote control unit every 5 minutes)

7-1. Mounting on a Wall

Before mounting the remote control unit, press the
ON/OFF operation button at the mounting location to
make sure that the air conditioner operates from that
location. The indoor unit should make a beeping sound
to indicate that it has received the signal.
11:50 AM
Page 29
Nut
Tightening Torque
Approx. 120 – 160 lbs·in (140 – 180 kgf·cm)
Approx. 300 – 360 lbs·in (340 – 420 kgf·cm)
Approx. 430 – 540 lbs·in (490 – 610 kgf·cm)
Approx. 590 – 710 lbs·in (680 – 820 kgf·cm)
Remote control
unit mount
Mounting screws
5/32
5/8" (4
16 mm)
(included)
Fig. 60c
Press
Set in
place
To take out the remote control unit, pull it forward.
Fig. 61
29
Torque wrench
Fig. 60d
Be sure to tighten the
flare nut using the
CAUTION
prescribed torque.
If the nut is over-
tightened, refrigerant
leakage may occur.
Rear side
Hole
To prevent loss of the remote control
unit, you can connect the remote
control unit to the mount by passing
a string through the remote control
unit and attachment hole.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ks3682C3682C3082

Table of Contents