activities.
G-Sensor use : enable/disable G-sensor use
Record : record camera input image with G-sensor communication.
Alarm: output alarm to selected channel with G-sensor communication.
Remote notification : Send notification to configured IP address with G-sensor communication.
Sensitivity : adjust G-Sensor shock detection level from ±0.1G to ±3G on each axis(X, Y, Z).
Sensitivity level is 1~30(±0.1G to ±3G) on each axis(X, Y, Z). Default value is 5(±0.5G). Record,
alarm and remote alarm are triggered when G-Sensor detects more than configured level.
Note
: Able to G-Sensor direction with using the switch on IO BOX.