Replacing A Failed Sfp Module; Unlocking The Sfp Module Latch - Plastic Variety - IBM TotalStorage DS4500 User Manual

Fibre channel storage server
Hide thumbs Also See for TotalStorage DS4500:
Table of Contents

Advertisement

1. Remove the LC-LC Fibre Channel cable from the SFP module that has failed.
For more information, see "Handling fiber-optic cables" on page 5 and
"Removing an LC-LC Fibre Channel cable from an SFP module" on page 8.
2. Replace the protective caps on the LC-LC Fibre Channel cables.
Figure 46. Replacing a failed SFP module
3. Unlock the SFP module latch:
v For SFP modules that contain plastic tabs, unlock the SFP module latch by
pulling the plastic tab outward 10°, as shown in Figure 47.
Plastic tab
Protective cap
o
10
Figure 47. Unlocking the SFP module latch - plastic variety
v For SFP modules that contain wire tabs, unlock the SFP module latch by
pulling the wire latch outward 90°, as shown in Figure 48 on page 62.
SFP module
Chapter 3. Replacing the DS4500 Storage Server components
61