Automatic Flow Control Valve; Field Installation For External Flue Terminal Or Draught Divertor; General Information; Installation Procedures - Jandy Lite 2 LG Installation And Operation Manual

Pool and spa heater (natural gas or lpg gas)
Hide thumbs Also See for Lite 2 LG:
Table of Contents

Advertisement

LITE 2 MODEL LG POOL AND SPA HEATER
11. If a header bolt is stripped in the process of
reassembly, drive it out of the header plate
and replace it (see Section 6, Parts List).
4F. Automatic Flow Control Valve
The automatic flow control valve has only one
moving part, normally requires no service, and will
withstand normal pool water for many years. Ex-
tremely high acid or chlorine concentration or hard
water could damage valve parts.
To determine if the valve is stuck open:
1. Shut off the filter pump.
2. Remove the flow control cap.
3. Make a visual inspection of the disc. If the
disc is not properly seated, or does not move
smoothly back and forth on the shaft, disas-
semble the valve and overhaul it
(see Fig. 29).
4. If parts are pitted due to corrosion by exces-
sive acid or chlorine in the pool water, they
should be replaced (see Section 6, Parts List).
SECTION 5.
Field Installation for External Flue
Terminal or Draught Divertor
5A. General Information
These instructions apply to all external flue
terminal (outdoor installation only) and draught
Figure 29. Flow control assembly.
Inlet/Outlet
Header
Disc
divertor (indoor installation only) Lite 2 pool and spa
heaters, Sizes 125 through 400.
This product must be installed and serviced by
a professional service technician, qualified in
pool and spa heater installation and
maintenance. Improper installation and/or
operation can cause nausea or asphyxiation
from carbon monoxide in flue gases which
could result in severe injury, property
damage, or death. Improper installation and/
or or operation will void the warranty.
When installing a new pool heater that will
connect to existing flueing, some adaptation of the flue
system will be required. This is due to variations in
flue centerlines with the replacement heaters. Refer to
the heater installation instructions for details of the
required flue system and appropriate standards.
5B. Installation Procedures
Zodiac Pool Systems, Inc., ships the LG heaters
with the low-profile top for an outdoor installation. To
install either the Jandy draught divertor (required on
all indoor installations) or the external flue terminal
(outdoor installations), follow these procedures:
1. Remove the top plate, stamped "HOT", by
slipping a fine-blade screwdriver into the slot
and prying it up (see Fig. 30).
2. Remove the top by removing all eight screws
connecting it to the jacket (see Fig. 31).
Spring
Gasket
Nut
WARNING
Cap
Washer
Page 23
Bolt

Hide quick links: