To remove the water valve:
1.
Disconnect the 2 blue wires and the orange wire
from the cold water (C) solenoid.
2.
Disconnect the 2 blue wires and the brown wire
from the hot water (H) solenoid.
3.
Disconnect the valve outlet hose:
Note: The valve outlet hose is diffi cult to remove.
a. Squeeze the clamp and slide it back.
b. Carefully break the hose loose by inserting a
small fl at-blade screwdriver under the hose
to break the seal.
c. Remove the hose.
Cold Water
Outlet Hose
4.
Remove the single (6-mm) hex-head screw that
holds the valve to the cabinet.
5.
Move the valve horizontally to the right.
Pump
The pump consists of a 120 VAC, 60-Hz motor,
impeller, impeller housing, and a removable strainer
that helps prevent foreign objects from entering the
pump impeller and drain outlet.
•
The pump runs whenever the washer is in the
spin function of a cycle.
•
The pump runs if the water level control
overfl ow switch is closed and the washer is
plugged in. (Overfl ow protection)
•
The pump is capable of eliminating 17 gallons
(64 liters) per minute.
•
Recommended minimum standpipe diameter is
1
Hot Water
•
Standpipe maximum height is 96 inches,
measured from the fl oor at the washer location.
•
The pump motor has an approximate resistance
value of 10.6 Ω.
Operation of the pump can be checked by using
service test mode t05. (See
Specifi c failures associated with the pump can
initiate error codes E30 and E31. (See
Mode
– 35 –
1
/
inches.
4
Service Test Mode
.)
.)
Service Test
(Continued Next Page)