Parts required to install:
1.
Slide lift arm end cover up onto the lift arm and remove the nut and bolt which
secures the hanger and remove the hanger.
2.
Insert one buttite spacer onto the 3/8" N.C. hex head bolt.
3.
Using the 3/8" N.C. hex head bolt, guide the 1/2" buttite spacer inside the lift arm
assembly.
4.
Place the safety lock cover (#5) onto the hanger scale assembly hook. The safety
lock cover hole should be at the top of the scale hook.
5.
With the 3/8" N.C. hex head bolt and buttite spacer through the one side of the
1/2" hole on the boom channel insert the scale hanger assembly inside the boom
channel.
6.
Now insert the 3/8" N.C. hex head bolt through the safety lock and scale hook.
Expose only enough of the bolt to insert the second buttite spacer.
7.
After the second buttite spacer is in place, insert the 3/8" N.C. hex head bolt
through the 1/2" hole in the boom channel. Both buttite spacers should be flush
with the outside surfaces of the lift arm assembly.
8.
Attach the 3/8" N.C. nylock nut to the hex head bolt, tighten the nylock nut until
one thread extends past the end of the hex nut.
DO NOT OVER TIGHTEN!

SCALE ATTACHMENT (OPTIONAL)

1 - 3/8" N.C. x 2" hex head bolt
1 - 3/8" N.C. nylock nut
2 - 3/8" x 1/2" buttite spacer