PROBLEM OR CONCERN
Gun/Hose - Leaking water
Leaking Oil from Pump
Leaking water from bottom
of unit
Low pressure
Not building maximum Pres-
sure
Irregular Pressure
No water coming out of Wand Clogged Nozzle
POSSIBLE CAUSE
Machine Inlet connection is de-
fective
Pump housing is leaking water
Faucet not fully open or unit is not
receiving a full volume of water
Screen Filter is clogged
Gun or Hose failure
Kink in the Garden Hose or Hose
is wrapped on a storage wheel
Water leaking from either Hose
or Unit
Garden Hose length is too long Shorten the length of the Garden Hose. We recom-
Clogged Nozzle
Air in Pump
No Wand attached to the front
of the Gun
Quick Connect is attached in-
correctly
Sceen Filter is clogged
24
SOLUTION
Gun/Hose will need to be replaced. Replace-
ment parts are not available for the Gun/Hose.
Email us at customerservice@huskypow
erwasher.com for assistance or order onli-
ne at www.huskypowerwasher.com.
A small amount of leakage is normal. If leakage
occurs please contact use directly at customerser
vice@huskypowerwasher.com.
Check the Machine Inlet at the front of the unit to
ensure that water is not leaking from it. If the con-
nection is leaking it will have to be replaced.
Contact us at customerservice@huskypo
werwasher.com or order a replacement
directly
online
at
www.huskypowe-
rwasher.com .
Email us at customerservice@huskypow
erwasher.com for assistance.
Open the faucet all the way.
Clean the Screen filter as instructed in the section 5.4.
Replace Gun and/or Hose. Contact us at custome
rservice@huskypowerwasher.com or order
online at www.huskypowerwasher.com.
Unwrap the Garden Hose and lay it out flat to
ensure that there are no kinks in the Hose.
Stop water from leaking before using the unit
or contact us if you need assistance.
mend a maximum length of 25 to 50 feet for City
water supply and 30 feet for Well water supply.
Clean the Nozzle as instructed in section 5.2.
Let Pressure washer run with Gun trigger de-
pressed and Wand removed until a steady
stream of water is released.
Attach either the Turbo or Adjustable Wand to
the front of the Gun. (High Pressure is created
with the Wand and not the Gun).
Clean Nozzle as instructed in section 5.2.
See section 3.2. To Attach Quick Connect pro-
perly, keep the outer collar of the Quick Con-
nect held back while sliding the Quick Connect
all the way forward against the Inlet Nipple
and then release the collar to lock it into place.
(The collar is spring loaded so if it is released
too soon it will not lock into place).
Clean the Sceen filter as instructed in section 5.4.