Electrical Requirements

The electrical wiring on disposers shipped from the factory are
not connected for a specific voltage. Refer to the Standard Motor
Connection Wiring Diagram attached to the inside of the disposer
terminal box cover for the correct voltage connections.
Standard disposer voltages are:
115/208/230 volts for single phase electrical power
208/230/460 volts for three phase electrical power
SS-50
1/2 H.P.
SS-75
3/4 HP
SS-100
1 H.P.
SS-125
1-1/4 H.P.
SS-150
1-1/2 H.P.
SS-200
2 H.P.
SS-300
3 H.P.
SS-500
5 H.P.
Service Manual
-26
115/208-230V, 60Hz, 1 Ph, 8.4/4.0/4.2 amps, UL
-27
208-230/460V, 60Hz, 3 Ph, 2.0/2.1/1.1 amps, UL
-28
115/208-230V, 60Hz, 1 Ph. 8.4/4.0/4.2 amps, CSA
-29
208-230/460V, 60Hz, 3 Ph, 2.0/2.1/1.1 amps, CSA
-27
115/208-230V, 60Hz, 1 Ph, 10.0/4.3/5.0 amps, UL
-28
208-230/460V, 60Hz, 3 Ph, 2.0/2.4/1.2 amps, UL
-29
115/208-230V, 60Hz, 1 Ph, 10.4/4.3/5.0 amps, CSA
-30
208-230/460V, 60Hz, 3 Ph, 2.0/2.4/1.2 amps, CSA
-28
115/208-230V, 60Hz, 1 Ph, 11.6/5.1/5.7 amps, UL
-29
208-230/460V, 60Hz, 3 Ph, 2.2/3.0/1.5 amps, UL
-30
115/208-230V, 60Hz, 3 Ph, 11.6/5.1/5.7 amps, CSA
-31
208-230/460V, 60Hz, 3 Ph, 2.2/3.0/1.5 amps, CSA
-25
115/208-230V, 60Hz, 1 Ph, 10.6/4.5/5.3 amps, UL
-26
208-230/460V, 60Hz, 3 Ph, 3.5/4.0/2.0 amps, UL
-27
15/208-230V, 60Hz, 1 Ph, 10.6/4.5/5.3 amps, CSA
-28
208-230/460V, 60Hz, 3 Ph, 3.5/4.0/2.0 amps, CSA
-34
115/208-230V, 60Hz, 1 Ph, 12.2/5.7/6.1, amps, UL
-36
208-230/460V, 60 Hz, 3 Ph, 3.2/4.6/2.3 amps, UL
-37
208-230/460V, 60 Hz, 3 Ph, 3.2/4.6/2.3 amps, CSA
-38
115/208-230V,, 60 Hz, 1 Ph, 12.2/5.7/6.1 amps, UL, short body
-39
208-230/460V, 60 Hz, 3 Ph, 3.2/4.6/2.3 amps, UL, short body
-35
115/208-230V, 60 Hz, 1 Ph, 12.2/5.7/6.1 amps, CSA
-27
115/208-230V, 60 Hz, 1 Ph, 17.4/7.7/8.7 amps, UL
-29
208-230/460V, 60 Hz, 3 Ph, 3.3/5.0/2.5 amps UL
-31
115/208-230V, 60 Hz, 1 Ph, 17.4/7.7/8.7 amps, UL, short body
-32
208-230/460V, 60 Hz, 3 Ph, 3.3/5.0/2.5 amps, UL, short body
-28
115/208-230, 60 Hz, 1 Ph, 17.4/7.7/8.7 amps, CSA
-30
208-240/460V 60Hz, 3 Ph, 3.3/5.0/2.5 amps, CSA
-25
208-230/460V, 60 Hz, 3 Ph, 6.0/7.4/3.7 amps, UL
-27
208-230/460V, 60 Hz, 3 Ph, 6.0/7.4/3.7 amps, UL, short body
-26
208-230/460V, 60 Hz, 3 Ph, 6.0/7.4/3.7 amps, CSA
-28
208-230/460V, 60 Hz, 3 Ph, 8.4/8.8/4.4 amps, UL
-30
208-230/460V, 60 Hz, 3 Ph, 8.4/8.8/4.4 amps, UL, short body
-29
208-230/460V, 60 Hz, 3 Ph, 8.4/8.8/4.4 amps, CSA
Commercial Disposers
NOTE: All amp ratings denote amp draw during a grind load.
NOTE: The disposer motor phase and voltage must be the same
as the line or power supply.
ELECTRIC SHOCK! The disposer must be
DANGER
permanently grounded.