Mitsubishi Electric PUHZ-P100VHA.UK Service Manual page 65

Split-type, heat pump air conditioners outdoor unit
Table of Contents

Advertisement

SW2 setting
The number of connected indoor units
ON
1
2 3 4 5 6
Capacity setting display
ON
1
2 3 4 5 6
Outdoor unit setting information
ON
1
2 3 4 5 6
Indoor pipe temperature / Liquid
(TH2(1))
ON
Indoor 1
– 39~88
1
2 3 4 5 6
Indoor pipe temperature / Cond. / Eva.
(TH5(1))
ON
Indoor 1
– 39~88
1
2 3 4 5 6
Indoor pipe temperature / Liquid
(TH2(2))
ON
Indoor 2
– 39~88
1
2 3 4 5 6
Indoor pipe temperature / Cond. / Eva.
(TH5(2))
ON
Indoor 2
– 39~88
1
2 3 4 5 6
Indoor room temperature (TH1)
8~39
ON
1
2 3 4 5 6
Display detail
65
Explanation for display
0~3
(The number of connected indoor units are dis-
played.)
Displayed as an outdoor capacity code.
Capacity
Code
20
P100V
25
P125V
28
P140V
• The tens digit (Total display for applied setting)
Setting details
Display details
H·P / Cooling only
0 : H·P
Single phase / Three phase
0 : Single phase 2 : Three phase
• The ones digit
Setting details
Display details
Defrosting switch
0 : Normal
(Example) When heat pump,three phase and
defrosting (normal) are set up, "20" is
displayed.
– 39~88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
– 39~88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
– 39~88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
– 39~88
(When the temperature is 0: or less, "–" and
temperature are displayed by turns.)
8~39
Unit
Unit
Code
display
1 : Cooling only
Code
display
1 : For high humidity
:
:
:
:
: