Preparing Work For Installation; Cover Pipe And Cover Side Remove; Open Panel Front; Drain Hose Junction - LG A2UN186FA0 Service Manual

Inverter multi type room air conditioner
Table of Contents

Advertisement

(3) Art Cool Type Indoor Unit

1) Preparing work for Installation

The wall you select should be strong and solid enough
to prevent vibration

1. Open panel front

• First,Pull the grille bottom, then remove screws
(2 pieces), and close grille bottom again.
• The moment of lifting the both lower parts of panel
front, you can hear sound this panel came out, In
this time panel front is separated
• After pull down this panel a bit, and separate con-
necting wire with product.
Panel Front
Connector
-46-

2. Cover pipe and cover side remove

• Remove two screws(for fixing cover pipe)
• Pull up the cover side of desired connecting direc-
tion, then cover side is separated.
• In case connecting direction is left or right, path
through the hole of cover side.
CAUTION
After removing the pipe hole, cut the burr for safety.
Pipe hole
NOTE: When connecting pipe path through rear
wall, don't remove the hole.

3. Drain hose junction

• Remove the rubber stopple of desired drain direction.
• As the following picture, Insert drain hose in the han-
dle of drain pan, and join drain hose and connecting
hose.
Adhesive
Connecting
part
Drain
hose
Only one
desiring direction
rubber cap