Installation

Select the best Location

Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles
in front of the unit.
3. Make sure that condensation drainage can
be conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and
the left (or right) of the unit is more than
200 mm. The unit should be installed as low
as possible on the wall, allowing a minimum
of 50 mm from floor.
6. Use a stud finder to locate studs to prevent
unnecessary damage to the wall.

Preparing Work for Installation

Open panel front
1. Remove the five screws.
2. Release the claws in the 3 places indicated.
3. Pull up the Front Panel.
Cover pipe and cover side remove
1. Pull up the side cover of desired connecting
direction, then cover side is separated.
2. Pick the pipe hole of the side cover.
After removing the pipe hole, cut the
burr for safety.
When making pipe path through rear
NOTICE
wall, you don't need to pick the pipe
hole.
Drain hose junction
1. Remove the rubber stopple in the left side
drain hole. (Do not use the right side drain
hole)
2. Insert drain hose into the handle of drain
pan, and join drain hose and connecting
hose according to the figure by.
14
Indoor Unit
More than 200 mm
More than 200 mm
More than 50 mm
1
More than 200 mm
More than 50 mm
More than 200 mm
Claw
2
3