The Outdoor Unit Does Not Operate At All - LG A2UN186FA0 Service Manual

Inverter multi type room air conditioner
Table of Contents

Advertisement

The Outdoor Unit does not operate at all.

Trouble 6
Does the Operating LED of indoor unit blink
when Operation's ON?
Is the Connection between CN-Power of
indoor unit and terminal block?
Is the connection of cable between indoor
and outdoor unit right?
Is the voltage of CN-POWER
door PCB Ass'y about AC220V / 240V ?
Is the operation of outdoor Ass'y right?
(IC04D, IC01A)
Replace the PCB Ass'y.
YES
NO
NO
YES
NO
YES
NO
,
in out-
YES
NO
NO
-96-
Refer to the self-diagnosis function.
Check the connecting state of connector
Indoor
Outdoor
1(Brown)
1(Brown)
2(Blue)
2(Blue)
3(Green/YL)
3(Green/YL)
4(Red)
4(Red)
Check the Fuse of Outdoor PCB Ass'y.
Check the connecting state of wires.
Replace the parts.