How To Correct Problems In The Machine - Clarke Focus II Mid-Size Autoscrubber Disc 26 Operator's Manual

Clarke focus ii mid-size autoscrubber
Hide thumbs Also See for Focus II Mid-Size Autoscrubber Disc 26:
Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
The machine does not remove all the
water from the fl oor.
The batteries do not give the normal
running time.
The cleaning is not even.
The machine does not run.
Clarke
®
Operator's Manual (EN) - FOCUS II MID-SIZE AUTOSCRUBBER

HOW TO CORRECT PROBLEMS IN THE MACHINE

CAUSE
The squeegee is up
The vacuum tank is full.
The screen fi lter is dirty.
There is an obstruction or damage in the
squeegee, squeegee hose or standpipe.
The vacuum motor is not running.
The squeegee hose is disconnected.
The squeegee blade is damaged, worn, or in-
correctly installed.
The gasket on the cover of the recovery tank
is damaged.
The recovery drain hose valve is not
closed.
The battery terminals are dirty or damaged.
The electrolyte level is too low.
The batteries are not fully charged.
The charger is damaged.
The battery is defective.
The batteries are disconnected.
The scrub brushes or pads are worn.
There is damage to the brush assembly, cast-
ers or the solution valve.
One or both brush motors are not running
The solution level is low.
The machine loses power.
ENGLISH
ACTION
Lower the squeegee.
Drain the tank.
Clean the screen fi lter.
Remove the obstruction or repair the damage.
Check for blown fuse. Have an authorized service per-
son make repairs.
Connect the hose.
Turn or replace the squeegee blade.
Correctly install the squeegee blade.
Replace the gasket.
Close valve.
Clean the terminals and connectors. Replace
the damaged cables. Charge the batteries.
Add distilled water to each cell and charge the batter-
ies.
Charge the batteries for a full 16 hour charge.
Have an authorized service person repair the charger.
Have an authorized service person check voltage of
each cell while discharging.
Connect the batteries.
Replace the scrub brushes or pads.
Have an authorized service person make the needed
repairs.
Check for tripped breaker, reset. Check for loose
connections.
Fill the solution tank.
NOTE: If the motors continue to stop consult an autho-
rized service person.
Reset the circuit breaker.
Check wire connection to traverse motor.
Replace the fuses.
Check the batteries connections.
Release parking brake (if installed)
NOTE: If the motors continue to stop, consult an au-
thorized service person.
®
EN
FORM NO. 71483A - 25 -

Advertisement

Table of Contents
loading

Table of Contents