Installing The Built-In Thermostatic Mixer - Mira Moto Installation & User Manual

Hide thumbs Also See for Mira Moto:
Table of Contents

Advertisement

Installing the Built-in Thermostatic
Mixer
1. carefully remove the concealing cap from the
control knob.
2. Unscrew the grubscrew using a .5 mm
hexagonal key (supplied) and pull off the
control knob(s).
Flow control Knob
Grubscrew
concealing cap
3. carefully remove the concealing ring from the
concealing plate.
concealing plate
control Knob
Grubscrew
concealing cap
temperature
control Knob
concealing ring
4. determine the route for the hot and cold
supply pipework and for the outlet pipework.
When connecting to the BIV shower fittings it
is recommended that the outlet be positioned
to one side of the mixer. this is to prevent
the flexible hose from obstructing the shower
controls (refer to illustration).
alternative pipe layouts
thermostatic
mixer
hot Inlet
5. mark the routes for the hot and cold supply
pipework at 03 mm centres (Hot - Left, Cold
- Right).
Note! If it is not possible to install the
mixer with this pipework configuration follow
instruction 6.
Falling Supplies: For falling supplies loosen
the grubscrew on each elbow using the .5 mm
hexagon key (supplied). remove the elbows
and install on opposite sides. retighten the
grubscrews.
Important! make sure that the elbows are
pushed fully onto the mixer before tightening
the grubscrews
Important! A flow regulator is fitted inside the
cold inlet elbow (some models). this can be
removed for gravity fed / other low pressure
systems (0.5 bar or below), refer to section:
'Specifications, Flow Regulators'.

outlet pipe BIV
cold Inlet
03 mm
outlet pipe BIV

Hide quick links: