Troubleshooting Procedures; Sealed Top Burners - Amana Gas Freestanding BIG OVEN Service Manual

Table of Contents

Advertisement

Troubleshooting Procedures

!

Sealed Top Burners

Spark Ignition
Problem
Burner will not light.
"SPARK" at top burner
ignitors.
Burner will not light. No
"SPARK' at top burner
ignitors. Burner knob
pushed in and held in
"LITE" position.
No spark or only random
spark at one ignitor.
Interm ittent or
occasional spark after
unit is turned off.
Unit continues to spark
after it is turned off.
Sooting from burner
flam e.
WARNING
Possible C ause
• Burner venturi, caps or ignition
ports clogged.
• Poor ground on burner cap.
• Low gas pressure.
• W eak spark m odule.
• No 120 VAC to unit.
• M icro switch contacts not closing.
• Failed wiring or poor connection at
burner cap electrode and electrode
socket.
• Failed spark m odule.
• Electrode dirty, burner cap dirty.
• Cracked or broken electrode,
electrode wire or electrode socket.
• Cracked ignitor or a pinched ignitor
lead wire.
• Poor connection of ground or lack
of continuity to ground of ignitor.
• Cracked or broken ignitor extension
lead.
• Reversed polarity. W hen polarity is
correct, no voltage is present at
neutral to ground and no voltage to
spark m odule with switch in "O FF"
position.
• Failed valve switch.
• Switch has been pulled up and off
of fixed position on valve so that it is
not turned to "O FF" position w ith
valve stem .
• Too little prim ary air.
• Burner head not positioned
correctly.
• If using LP gas, range m ay not be
properly converted.
To avoid risk of electrical shock, personal injury or
death, disconnect power and gas supply before
servicing, unless testing requires it.
• Clean burner venturi, caps, and ignitor
ports.
• Clean burner cap.
• Verify correct gas pressure.
• Replace spark m odule.
• Verify electricity at wall outlet.
• Verify correct w iring and connection
are tight.
• Verify correct w iring and connection's
are tight.
• Verify operation of spark m odule.
Replace if failed.
• Clean electrode and burner cap.
• Replace electrode wire.
• Replace ignitor lead or electrode.
• Tighten ground connection and correct
any breaks in ground path from ignitor
to unit ground.
• Replace ignitor.
• W ith all switches in the "O FF" position,
verify voltage at "N" term inal of the
spark m odule to ground. If voltage is
present, polarity is reversed.
• Verify correct w iring and connection's
are tight.
• Verify wiring is not pinched.
• Replace switch.
• Carefully reposition switch on valve
stem and rotate valve from "O FF" to
"HIG H" several tim es to verify switch is
not broken.
• O pen air shutter.
• Level burner head.
• Verify correct conversion procedures.
Som e yellow tipping is norm al on LP.
15
Correction
RS2310005 Rev. 0

Advertisement

Table of Contents
loading

Table of Contents