Kramer VS-4228 User Manual

8-port rs-422 matrix switcher
Hide thumbs Also See for VS-4228:

Advertisement

Quick Links

K R A ME R E LE CT R O N IC S L TD .
USER MANUAL
MODEL:
VS-4228
8-Port RS-422 Matrix Switcher
P/N: 2900-002033 Rev 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VS-4228 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kramer VS-4228

  • Page 1 K R A ME R E LE CT R O N IC S L TD . USER MANUAL MODEL: VS-4228 8-Port RS-422 Matrix Switcher P/N: 2900-002033 Rev 5...
  • Page 3: Table Of Contents

    Technical Specifications Default Communication Parameters Hex Codes Figures Figure 1: VS-4228 8-Port RS-422 Matrix Switcher Front Panel Figure 2: VS-4228 8-Port RS-422 Matrix Switcher Rear Panel Figure 3: Bi-directional Signals I Figure 4: Bi-directional Signals II Figure 5: Connecting the VS-4228 8-Port RS-422 Matrix Switcher...
  • Page 4: Introduction

    Introduction Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded...
  • Page 5: Getting Started

    Avoid interference from neighboring electrical appliances that may adversely influence signal quality  Position your Kramer VS-4228 away from moisture, excessive sunlight and dust This equipment is to be used only inside a building. It may only be connected to other equipment that is installed inside a building.
  • Page 6: Recycling Kramer Products

    Kramer Electronics has made arrangements with the European Advanced Recycling Network (EARN) and will cover any costs of treatment, recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility. For details of Kramer’s recycling arrangements in your particular country go to our recycling pages at http://www.kramerelectronics.com/support/recycling/.
  • Page 7: Overview

    Overview The VS-4228 is a high-performance bidirectional matrix switcher for RS-422 control signals. It can connect multiple ports to create from one to four bidirectional communication groups. In particular, the VS-4228 features:  Simple-to-connect automatic master/slave configuration  A bright LED display showing the status of the matrix switcher ...
  • Page 8: Figure 1: Vs-4228 8-Port Rs-422 Matrix Switcher Front Panel

    Figure 1: VS-4228 8-Port RS-422 Matrix Switcher Front Panel Feature Function Power Switch Illuminated switch that turns power ON and OFF MASTER Buttons Select the MASTER to switch to the SLAVE SLAVE Buttons Select the SLAVE to which the MASTER is switched...
  • Page 9: Figure 2: Vs-4228 8-Port Rs-422 Matrix Switcher Rear Panel

    Figure 2: VS-4228 8-Port RS-422 Matrix Switcher Rear Panel Feature Function RS-422 9-pin D-sub Connectors RS-422 bi-directional ports (1-8) CONTROL RS-485 Terminal Block Connector Connector for external RS-485 control (PINOUT: G, -, +) CONTROL RS-232 IN 9-pin D-sub Connector Connect to the PC serial port...
  • Page 10: About Rs-422

    Figure 3 illustrates: Figure 3: Bi-directional Signals I When a master device changes position with a slave device, the pins automatically change, as Section 3.2.4 describes and as Figure 4 illustrates: Figure 4: Bi-directional Signals II VS-4228 - Overview...
  • Page 11 VTR may become a master for a second VTR. 3.2.4 Automatic Configuration After connecting the 9-pin D-sub connectors and cables between the controlled units, the VS-4228 automatically configures which pins to use in the 9-pin D-sub connector according to the assignment of each machine. 3.2.5 Port Definitions Modern equipment usually has only one connector, RS-422, which functions as a master as well as a slave.
  • Page 12 # 7 is the master, and ports # 5, # 3 and # 6 are slaves, the VS-4228 only transmits to the master the reply from port # 3 and discards all the other replies.
  • Page 13: Connecting The Vs-4228

    Figure 2. If RS-232 control is required, connect a PC via the null-modem adapter (when using the Kramer Control software or other controller) as described in Section 4.1. 3. If RS-485 control is required, connect a cable to the RS-485 terminal block, as described in Section 4.2.
  • Page 14: Connecting A Pc Or Controller To The Rs-232 Port

    Method A above) only requires pins 2, 3 and 5 to be connected, you are free to decide whether to connect only these 3 pins or all 9 pins. Null-Modem to PC Adapter Figure 7: Straight Cable RS-232 Connection with a Null Modem Adapter VS-4228 - Connecting the VS-4228...
  • Page 15: Connecting A Pc Or Controller To The Rs-485 Port

    Connecting a PC or Controller to the RS-485 Port You can operate the VS-4228 via the RS-485 port from a distance of up to 1200m (3900ft) using any device equipped with an RS-485 port (for example, a PC). For successful communication, you must set the RS-485 machine number and bus termination.
  • Page 16: Figure 8: Cascading Units Via The Rs-232 Control Interface

    To connect an RS-485 connector on one VS-4228 unit to an RS-485 connector on another unit: 1. Connect the “+” PIN on the first VS-4228 unit to the “+” PIN on the second VS-4228 unit 2. Connect the “-” PIN on the first VS-4228 unit to the “-” PIN on the second...
  • Page 17: Figure 9: Cascading Units Via The Rs-485 Control Interface

    (connect the PC’s 9-pin D-sub COM port to the “RS-232 in” 9-pin D-sub (F) port on the VP-43xl. Next, connect the RS-485 port on the VP-43xl to the RS-485 ports on the VS-4228 units) Figure 9: Cascading Units via the RS-485 Control Interface Note: When cascading multiple units using the RS-485 interface, you must connect a 100Ω...
  • Page 18: Operating The Vs-4228

    Slave devices: Port 3 – Video Player 1 Port 4 – Video Player 2 Port 8 – Video Recorder The following examples show how to operate the VS-4228: 1. To connect the PC to Video Player 2:  Press SLAVE 4, then MASTER 1.
  • Page 19 4. To disconnect the PC from the Video Player 2 in the previous status:  Press SLAVE 4 and OFF. The following status displays: 5. To disconnect all masters:  Press ALL, then OFF. The following status displays: VS-4228 - Operating the VS-4228...
  • Page 20: Technical Specifications

    19” x 7” x 1U (W, D, H) rack-mountable DIMENSIONS: 032V AC, 50/60 Hz, (115V AC, U.S.A.) 10VA POWER CONSUMPTION: WEIGHT: 2.2kg (4.88lbs) approx INCLUDED ACCESSORIES: Power cord, Windows® Control Software Specifications are subject to change without notice at http://www.kramerelectronics.com VS-4228 - Technical Specifications...
  • Page 21: Default Communication Parameters

    Default Communication Parameters RS-232 Protocol 2000 Baud Rate: 9600 Data Bits: Stop Bits: Parity: None Command Format: Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81 VS-4228 - Default Communication Parameters...
  • Page 22: Hex Codes

    The following table includes Protocol 2000 hexadecimal codes (the protocol uses 4 bytes of information, data is at 9600 baud, no parity, 8 data bits and one stop bit). Full details are available at our web site: www.kramerelectronics.com. VS-4228 - Hex Codes...
  • Page 23 VS-4228 - Hex Codes...
  • Page 24 For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found. We welcome your questions, comments, and feedback. Web site: www.kramerelectronics.com E-mail: info@kramerel.com SAFETY WARNING...

Table of Contents