3.4 Initial Reset Circuit
Fig 3.4-1 Initial Reset Circuit of iDP562-CNL
Fig 3.4-2 Initial Reset Circuit of iDP562-RSL and iDP562-RSL2
3.5 Power Source
All voltage needed in actuating the printer are supplied. They are DC +5V and DC +12V.
Rated voltage
+5V
+12V
CITIZEN
Where to used
LSI, TTL, other control system
Related components of the printer
14
iDP-562 Service Manual