The heat pump has four separate fluid circuits
Brine circuit – a water based mixture that transports energy from the heat source to the heat pump.
Refrigerant circuit – a circuit in the heat pump that through evaporation, compression and condensation takes
energy from the refrigerant circuit and supplies it to the heat transfer fluid circuit. The refrigerant is chlorine free.
Heat transfer fluid circuit – the water that transports the heat/energy to the heating system and the water heater.
Hot gas circuit – is a high temperature circuit for the hot water circuit's final heater. If the heat pump is not con-
nected to any water heaters, the hot gas circuit does not need to be connected.
2.3

Water heater

Danfoss DHP-R Eco can also produce hot water for an external water heater. The water temperature of the hot water tank is
controlled by the control switch and cannot be adjusted.
Hot water production stops when the control pressostat reaches its maximum operating pressure.
2.4

System overview

Danfoss DHP-R Eco can be configured in a number of different combinations, one of which is shown below. The image illus-
trates a Danfoss DHP-R Eco heat pump with four water heaters, the final heater of which is connected to the heat pump's
hot gas circuit.
Additional shunt
(0-10V)
Brine
2.5

Room sensor (option)

As an option, the heat pump system can be equipped with a room sensor of the Active type = 24 VAC 0-10V.
Only authorised electricians may carry out the installation.
For connection, see the separate manual for the control system.
2.6

Piping installation

(Carried out in accordance with your Installer)
6
Heating system
Hot water
HWH
Hot gas circuit
TWC Communication
HWH
HWH
VUIFK102
CW
HW
HWC
HWH
CW = Cold Water
HW = Hot Water
HWC = Hot Water Circulation
HWH = Hot Water Heater