JUNCTION BOX
REM
FAN OUTLET RECEPTACLE
PLUG-IN
3V TRANSFORMER
LOW VOLTAGE
SEE NOTE 1
IGNITION
MODULE
(3V)
OPTIONAL
BATTERY
BACK-UP
ON/OFF
WALL SWITCH
VALVE
GROUND
NEUTRAL
22
JUNCTION BOX
120 VAC
120 VAC
REM
FAN
FAN
WALL SWITCH
(NO FAN OPTION)
OPTIONAL
FLAME SPARKER/
REMOTE
SENSOR
LOW VOLTAGE
SEE NOTE 1
REMOTE
CONTROL
HOT
Figure 10. Intermittent Pilot Ignition (IPI) Wiring Diagram
Heat & Glo • PIER-TVFL, ST-42TVFL-IPI • 455-901 Rev. F • 8/05
TRANSFORMER
3 VAC
IGNITION MODULE 3 VAC
BRN
BRN
OPTIONAL
BATTERY BACKUP
For Intermittent Pilot Ignition (IPI) Wiring
Appliance Requirements
This appliance requires that 110-120 VAC be wired to
the junction box. Maintain correct polarity when wiring
the junction box.
Operation using Battery Power
This fireplace has an optional battery operation. The
system is fully functional with the use of two "D" size
batteries without ordinary 110-120 VAC power.
Wiring to the battery pack should be left disconnected
in order to conserve battery life. In the case of a loss of
power, simply connect red and black wire leads to
activate battery power (connect red to red, black to
black). The fireplace can be used as necessary. Once
power (110 VAC) is restored, disconnect red and black
wire leads to extend battery life.
INTERMITTENT PILOT IGNITOR
I
S
ORG
WHT
GROUND TO
FIREPLACE
CHASSIS
GRN
VALVE