Note
You may receive a different
number of status beeps if
buttons are pressed quickly
Simon Security System
Status Beeps
Status beeps are used to indicate key presses, status, and problems with the system.
They can be enabled or disabled (see "Options"). The following table describes status
beep activity.
.
Activity
ARM Doors & Windows
ARM Motion Sensors
ARM Doors/Windows &
Motion Sensors
DISARM
CHIME DOORS
CHIME SPECIAL MOTION
Trouble Beeps
No Activity Beeps
Alarm Sirens and Lamp Modules
Exterior and interior sirens make 3 different alarm sounds on the premises, each indi-
cating a different type of alarm. Sirens are programmed by the installer to time-out and
stop sounding after a specified time.
Use the following table to understand the siren sounds used by the security system.
Temporal 3 refers to a continuous pattern of 3 siren pulses then off for 1.5 seconds, 3
siren pulses then off for 1.5 seconds.
Alarm Siren and X10 Light Information
X10 Lights
X10 Siren
Interior & Panel Siren
Exterior Siren
Status Beeps
Beep Response
Exit delay and Entry delay beeps sound 2 times
every 5 seconds and 2 times per second during
the last 10 seconds (if Silent Exit is used, the Exit
delay beeps will only sound twice when you arm
and twice when the Exit delay expires)
Exit delay and Entry delay beeps sound 3 times
every 5 seconds and 3 times per second during
the last 10 seconds (if Silent Exit is used, the Exit
delay beeps will only sound 3 times when you arm
and 3 times when the Exit delay expires)
Exit delay and Entry delay beeps sound 4 times
every 5 seconds and 4 times per second during
the last 10 seconds (if Silent Exit is used, the Exit
delay beeps will only sound 4 times when you arm
and 4 times when the Exit delay expires)
1 beep
2 beeps (feature must be programmed by installer)
3 beeps (feature must be programmed by installer)
6 beeps every minute. Press the SYSTEM STA-
TUS button to stop beeps for 4 hours
20 beeps every minute for 5 minutes (feature must
be programmed by the installer)
Fire
Intrusion
Steady
Flashing
Steady
Steady
Temporal 3
Steady
Temporal 3
Steady
Emergency
Steady
Alarm beeps
Fast on/off
8
Need help?
Do you have a question about the Simon and is the answer not in the manual?