Typical Installation - Coleman HC6B024 THRU 060 Technical Manual

Echelon series split-system heat pumps 16 seer – r-410a – 1 phase 2 thru 5 nominal tons

Advertisement

ACCESSORIES
TXV Kits - S1-1TVM series thermal expansion valves precisely
meter refrigerant for optimum performance over a wide range of
conditions. See System Charge table for TXV part number for
each model.
Start Assist Kit (S1-2SA067) - Provides increased starting
torque for areas with low voltage. See Hard Start Kit Accessory
Installation Manual for Hard Start Kit part number for each
model.
Temperature Sensor (S1-37309243000) - The temperature
sensor is used to sense plenum temperature, and is optional
with a gas or oil back-up heat source. Compatible only with 13
SEER and higher heat pumps.
SOUND POWER LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
Size
Test Condition
Cooling Mode
24
Heating Mode
Cooling Mode
30
Heating Mode
Cooling Mode
36
Heating Mode
Cooling Mode
42
Heating Mode
Cooling Mode
48
Heating Mode
Cooling Mode - Stage 1
60
Heating Mode - Stage 1
Cooling Mode - Stage 2
60
Heating Mode - Stage 2
Rated in accordance with ARI Standard 270.

TYPICAL INSTALLATION

TO INDOOR
BLOWER
SEAL OPENINGS WITH
PERMAGUM OR EQUIVALENT
NOTES:
ALL OUTDOOR WIRING MUST BE WEATHERPROOF
MINIMUM 24" UNIT TO UNIT CLEARANCE
Johnson Controls Unitary Products
63
72
71
73
76
75
71
70
70
77
75
75
75
73
72
THERMOSTAT
NEC CLASS 1
NEC CLASS 2
WIRING
TO COIL
Dehumidistat (S1-2HU16700124) - Provides increased dehu-
midification when matched with variable speed furnace or air
handler.
Heat Pump Risers (S1-52635389000, S1-52635390000,
S1-52635391000) - 3", 6", or 12" risers mount easily in compos-
ite base pan recesses, ensuring the unit stays clear of snow
and ice build-up in harsh winter weather.
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance, these
outdoor units are fully compatiable with the Residential Touch
Screen Communicating Control S1-TTSCC01.
125
250
500
1000
76
69
67
67
79
70
68
67
70
67
68
69
72
69
69
66
79
70
69
67
80
64
61
62
69
72
68
68
71
72
67
64
78
72
70
66
82
73
72
66
75
70
68
64
76
69
68
66
78
69
68
64
81
70
69
66
WIRING
WEATHERPROOF
DISCONNECT
SWITCH
632152-CTG-E-0812
2000
4000
8000
62
58
53
62
58
55
61
55
48
61
57
60
61
56
49
58
54
53
60
55
47
60
55
48
61
56
50
61
58
54
61
56
50
60
56
51
61
56
50
63
58
51
60" OVERHEAD
CLEARANCE
10" CLEARANCE
AROUND PERIMETER
24" SERVICE
ACCESS
CLEARANCE
dBA
SQI
71
19.1
71
19.0
71
19.1
71
19.1
72
19.1
68
19.0
71
19.0
70
19.2
72
19.1
73
19.1
70
19.2
70
19.1
70
19.2
72
19.2