System Charge For Various Matched Systems - Coleman HC6B024 THRU 060 Technical Manual

Echelon series split-system heat pumps 16 seer – r-410a – 1 phase 2 thru 5 nominal tons

Advertisement

Outdoor Unit
1,2
Required TXV
3,4,5
Indoor Unit
AHE24B
AHE30B
AHE36C
AHE42D
AHE48D
AHE60D
AHR24B
AHR36B
AHR42C
AHR60D
AHV24B
AHV30B
AHV36C
AHV42D
AHV48D
AHV60D
AV*36
AV*48
FC/MC/PC32
FC/MC/PC35
FC/MC/PC37
FC/MC/PC43
FC/MC/PC48
FC/MC/PC60
FC/PC62
FC64
UC48
UC60
Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the "COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils" table.
FOOTNOTES:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. A TXV kit must be used with these indoor units to obtain system performance.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224.
4. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.
5. Refer to Cooling and Heating Performance Data tables for actual performance for specified system matches.
Note: If a TXV is factory installed on the coil, it must be replaced with the listed TXV.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of interconnecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and lineset length.
5. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + charge adder for matched indoor unit +
charge adder for line set.
Johnson Controls Unitary Products

System Charge for Various Matched Systems

HC6B024F3(C) HC6B030F3(C) HC6B036F3(C) HC6B042F4(C) HC6B048F3(C) HC6B060F3(C)
4N1
4H1
TXV + 0
TXV + 0
TXV + 0
TXV + 0
TXV + 0
TXV + 0
TXV + 0
TXV + 12
TXV + 0
TXV + 12
TXV + 0
TXV + 0
TXV + 0
TXV + 12
TXV + 0
TXV + 12
TXV + 0
4H1
Additional Charge, Oz
TXV + 0
TXV + 20
TXV + 0
TXV + 5
TXV + 0
TXV + 0
TXV + 0
TXV + 20
TXV + 0
TXV + 5
TXV + 20
TXV + 0
TXV + 0
TXV + 20
TXV + 0
TXV + 5
TXV + 15
TXV + 31
TXV + 2
632152-CTG-E-0812
4J1
4J1
TXV + 0
TXV + 0
TXV + 0
TXV + 0
TXV + 8
4K1
TXV + 0
TXV + 0
TXV + 0
TXV + 8
3