Coleman HC8B024F1 Technical Manual

Coleman HC8B024F1 Technical Manual

Echelon split-system heat pumps 18 seer – r-410a models: hc8b024 thru 060 (2 thru 5 nominal tons)

Advertisement

TECHNICAL GUIDE
Echelon
SPLIT-SYSTEM HEAT PUMPS
18 SEER – R-410A
MODELS:
HC8B024 THRU 060
(2 THRU 5 NOMINAL TONS)
LISTED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ari.org/aridirectory
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System

DESCRIPTION

The HC8BSeries unit is the outdoor part of a versatile heat pump
system. It is designed to be custom matched with one of our
complete line of evaporator sections, each designed to serve a
specific function. Matching air handlers are available for upflow,
downflow, and horizontal left or right application to provide a
complete system. Electric heaters are available if required. Add-
on coils are available for use with upflow, downflow, or horizontal
furnaces. Field installed accessories are available as needed.
WARRANTY
5-year limited parts warranty.
10-year limited compressor warranty.
Premium System Warranty - Limited lifetime compressor and 10-
year parts when matched with an approved Coleman Echelon
furnace or UPG air handler and coil.

FEATURES

• Superior Coil Protection – A PVC coated steel coil guard com-
pletely protects coil from debris and other large damaging material
while a polymer mesh further protects the coil against smaller par-
ticles.
• Isolated Compressor Compartment – A molded composite
bulkhead isolates the compressor from the rest of the unit reduc-
ing sound and vibration.
• Protected Compressors – Each compressor is protected against
high and low pressure as well as excessive temperature. This is
accomplished by by the simultaneous operation of a high pres-
sure relief valve and temperature sensors which protect the com-
pressor if undesirable conditions occur.
• Environmentally Friendly Refrigerant – Next generation refrig-
erant R-410A delivers environmentally friendly performance, with
zero ozone depletion.
• Durable Finish – Automotive quality finish provides the ultimate
protection from harmful U.V. rays as well as rust creep ensuring
long-lasting high quality appearance. A powder-paint topcoat is
applied over a baked-on primer, using a galvanized, zinc coated
steel base material. The result is a finish that has been proven in
testing to provide 33% greater durability than conventional pow-
der-coat finishes.
• Lower Installed Cost – Designed to provide enhanced installabil-
ity by featuring a slide-down control compartment allowing easy
access to control components along with angled service valves to
reduce overall installation time and cost.
• Low Operating Sound Levels – A fan design boasting technol-
ogy adapted from aeronautic and defense engineering provides
for whisper quiet operation by allowing airflow to flow smoothly
and efficiently across the fan tips.
• Filter-Drier – A factory installed, solid core liquid line filter-drier fil-
ters harmful debris and moisture from the system.
• Easy Service Access – A full end, full service, access panel with
handle makes for easy entry to internal components.
• Long Lasting Operation – Strong and durable composite base
pan provides added strength while resisting rust and corrosion as
well as reducing sound and vibration.
TM
• WhisperDrive
system - The swept-wing fan, composite base
pan, isolated compressor compartment and two-stage compres-
sor are engineered as a system to reduce overall sound to a mere
whisper.
• Complete System Control – All models utilize the exclusive
microprocessor based, on-demand, defrost control system. This
system provides optimal comfort, efficiency, and constant montor-
ing of the entire system for reliable operation. defrost cycles occur
only when necessary. an adjustable balance point insures supple-
mental heat is brought on only when required to meet the space
load, for optimum efficiency and reliability.
• In the event improper operating conditions occur (high tempera-
ture and/or high pressure), the unit will automatically shut down to
protect the refrigeration system, and switch to back-up heat. On-
board diagnostic LED's guide the technician to the source of the
problem, and an output signal from the control to the thermostat
will alert the homeowner. The control also features non-volatile
memory, which preserves trouble codes in the event of power
loss. An anti-short cycle timer extends the life of the compressor
by preventing short-cycling.
Certified in accordance with the Unitary Small Equipment certification
program, which is based on ARI Standard 210/240.
345095-CTG-B-0907

Advertisement

Table of Contents
loading

Summary of Contents for Coleman HC8B024F1

  • Page 1 TECHNICAL GUIDE 10-year limited compressor warranty. Premium System Warranty - Limited lifetime compressor and 10- Echelon year parts when matched with an approved Coleman Echelon furnace or UPG air handler and coil. SPLIT-SYSTEM HEAT PUMPS FEATURES 18 SEER – R-410A •...
  • Page 2 345095-CTG-B-0907 Physical and Electrical Data MODEL HC8B024F1 HC8B036F1 HC8B048F1 HC8B060F1 Unit Supply Voltage 208-230V, 1φ, 60Hz 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 16.3 22.0 27.9 33.4 Max. Overcurrent Device Amps Min. Overcurrent Device Amps Multi-stage Compressor Compressor Type...
  • Page 3 345095-CTG-B-0907 Additional R-410A Charge / TXV Size for Various Matched Systems Outdoor Unit HC8B024F1 HC8B036F1 HC8B048F1 HC8B060F1 1TVM903 1TVM906 1TVM906 1TMV906 Approved System Thermal Expansion Valve Factory R-410A Charge, lbs-oz 15 - 0 12 - 15 13 - 5 14 - 12...
  • Page 4 SEER TOTAL SENSIBLE 18 SEER HP WITH MV - VARIABLE SPEED 18.2 13.5 14.00 MV12B FC/MC43B 16.40 23.6 18.8 13.60 18.5 14.0 14.50 HC8B024F1 MV12D FC/MC48D 17.00 24.0 19.5 14.00 18.5 14.0 14.50 MV12D FC/MC60D 17.00 24.0 19.5 14.00 24.8 18.2...
  • Page 5 COOLING CAPACITY - With Variable Speed Furnaces COOLING VARIABLE SPEED COIL UNIT MODEL NET MBH RATED FURNACE MODEL MODEL STAGE SEER TOTAL SENSIBLE 18.0 12.9 14.10 HC8B024F1 FC9(C,V)*B12 FC/MC/PC43B 16.6O 23.6 18.9 13.30 24.6 18.1 14.20 (F,L)C8(C,V)*B16 FC/MC/PC43B 17.0O 1200 35.2 26.4 13.40...
  • Page 6 345095-CTG-B-0907 COOLING CAPACITY - With Variable Speed Furnaces (Continued) COOLING VARIABLE SPEED COIL UNIT MODEL NET MBH RATED FURNACE MODEL MODEL STAGE SEER TOTAL SENSIBLE 33.0 23.4 13.30 (F,L)C8(C,V)*C16 FC/MC/PC48C 16.3O 1500 46.0 34.6 11.70 1030 33.0 25.0 13.40 (F,L)C8(C,V)*C20 FC/MC/PC48C 16.4O 1610...
  • Page 7 STAGE HSPF COP @ 47 47 OD 17 OD 18 SEER HP WITH MV - VARIABLE SPEED 19.3 MV12B FC/MC43B 24.0 17.0 24.0 15.2 19.3 HC8B024F1 MV12D FC/MC48D 24.0 16.8 24.0 15.0 19.3 MV12D FC/MC60D 24.0 16.8 24.0 15.0 26.4...
  • Page 8 HEATING CAPACITY - With Variable Speed Furnaces HEATING VARIABLE SPEED COIL UNIT MODEL NET MBH RATED COP @ FURNACE MODEL MODEL STAGE HSPF 47 OD 17 OD 19.1 3.80 HC8B024F1 FC9(C,V)*B12 FC/MC/PC43B 24.2 17.1 3.90 23.8 15.0 3.20 26.4 4.00 (F,L)C8(C,V)*B16 FC/MC/PC43B 1200 36.0 26.6 9.35...
  • Page 9 345095-CTG-B-0907 HEATING CAPACITY - With Variable Speed Furnaces (Continued) HEATING VARIABLE SPEED COIL UNIT MODEL NET MBH RATED COP @ FURNACE MODEL MODEL STAGE HSPF 47 OD 17 OD 26.4 4.00 (F,L)C8(C,V)*C20 FC/MC62D 1200 36.0 26.2 9.55 4.20 36.0 23.8 9.35 3.20 26.4...
  • Page 10 345095-CTG-B-0907 HEATING CAPACITY - With Variable Speed Furnaces (Continued) HEATING VARIABLE SPEED COIL UNIT MODEL NET MBH RATED COP @ FURNACE MODEL MODEL STAGE HSPF 47 OD 17 OD 36.0 3.80 FC9(C,V)*D20 FC/MC/PC60D 1560 48.0 32.6 4.00 39.0 25.6 3.20 1030 36.0 3.80...
  • Page 11 345095-CTG-B-0907 ACCESSORIES* SOUND POWER RATINGS* (dBA) TXV Kits - 1TVM9 series thermal expansion valves precisely UNIT MODEL meter refrigerant for optimum performance. Cooling Heating Bonnet Sensor (2SB13700124) - The bonnet sensor is used to sense plenum temperature, and is optional with a gas or oil back-up heat source.
  • Page 12 345095-CTG-B-0907 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B024F1 INDOOR COIL MODEL NO. FC/MC/PC48D + MV12D ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 19.7 20.0 19.9 22.0 23.6 19.7 20.0...
  • Page 13 345095-CTG-B-0907 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B024F1 INDOOR COIL MODEL NO. FC/MC/PC48D + MV12D ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 24.9 26.6 26.4 28.8 30.9 25.8 27.2...
  • Page 14 345095-CTG-B-0907 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B036F1 INDOOR COIL MODEL NO. FC/MC62D + MV12D ID CFM CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 26.3 27.5 27.3 30.5 33.5 26.9 28.0 27.7 30.9...
  • Page 15 345095-CTG-B-0907 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B036F1 INDOOR COIL MODEL NO. FC/MC62D + MV12D ID CFM 1148 1248 1348 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 38.4 39.7 40.2 43.7 47.8 39.4...
  • Page 16 345095-CTG-B-0907 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B048F1 INDOOR COIL MODEL NO. FC/MC62D + MV20D ID CFM 1000 1050 1100 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 33.8 35.9 35.8 39.4 43.5 34.4...
  • Page 17 345095-CTG-B-0907 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B048F1 INDOOR COIL MODEL NO. FC/MC62D + MV20D ID CFM 1470 1570 1670 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 47.6 49.8 49.6 54.3 58.9 48.5...
  • Page 18 345095-CTG-B-0907 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B060F1 INDOOR COIL MODEL NO. FC/MC62D + MV20D ID CFM 1125 1175 1225 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 40.8 44.0 43.6 48.6 53.8 41.5...
  • Page 19 345095-CTG-B-0907 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B060F1 INDOOR COIL MODEL NO. FC/MC62D + MV20D ID CFM 1718 1818 1918 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 57.5 60.6 60.7 65.4 73.0 58.5...
  • Page 20 345095-CTG-B-0907 HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B024F1 INDOOR COIL MODEL NO. FC/MC/PC48D + MV12D AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 24.2 24.4...
  • Page 21 345095-CTG-B-0907 HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B024F1 INDOOR COIL MODEL NO. FC/MC/PC48D + MV12D AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 31.6 32.0...
  • Page 22 345095-CTG-B-0907 HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B036F1 INDOOR COIL MODEL NO. FC/MC62D + MV12D AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 31.2 31.5 31.8 30.7...
  • Page 23 345095-CTG-B-0907 HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B036F1 INDOOR COIL MODEL NO. FC/MC62D + MV12D AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1088 1188 1288 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 48.8...
  • Page 24 345095-CTG-B-0907 HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B048F1 INDOOR COIL MODEL NO. FC/MC62D + MV20D AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1023 1073 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 41.4 41.6...
  • Page 25 345095-CTG-B-0907 HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B048F1 INDOOR COIL MODEL NO. FC/MC62D + MV20D AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1423 1523 1623 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 59.6...
  • Page 26 345095-CTG-B-0907 HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B060F1 INDOOR COIL MODEL NO. FC/MC62D + MV20D AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1066 1116 1166 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 50.9...
  • Page 27 345095-CTG-B-0907 HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC8B060F1 INDOOR COIL MODEL NO. FC/MC62D + MV20D AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 1621 1721 1821 OUTDOOR INDOOR MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. UNIT COIL 72.8...
  • Page 28 NOTES Subject to change without notice. Printed in U.S.A. 345095-CTG-B-0907 Copyright © by Unitary Products Group 2007. All rights reserved. Supersedes: 345095-CTG-A-0907 Unitary 5005 Norman Products York Group Drive 73069...