Download Print this page
Coleman HC6B024 THRU 060 Technical Manual

Coleman HC6B024 THRU 060 Technical Manual

Echelon series split-system heat pumps 16 seer – r-410a – 1 phase 2 thru 5 nominal tons

Advertisement

Quick Links

TECHNICAL GUIDE
TM
ECHELON
SERIES
SPLIT-SYSTEM HEAT PUMPS
16 SEER – R-410A – 1 PHASE
2 THRU 5 NOMINAL TONS
MODELS: HC6B024 THRU 060
®
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at
www.upgnet.com and www.colemanac.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY SUMMARY*
Extended 10-Years limited parts warranty.
Extended Lifetime limited compressor warranty.
Extended parts and compressor warranties require online
registration within 90 days of purchase for replacement or
closing for new home construction.
* Does not apply to R-22 models, 3-Phase models, or internet sales.
See Limited Warranty certificate in User's Information Manual for details.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 16 SEER Series unit is the outdoor part of a versatile climate
system. It is designed with a matching indoor coil component from
Johnson Controls Unitary Products. Available for typical applica-
tions, this climate system is supported with accessories and docu-
ments to serve specific functions.
FEATURES
• Superior Coil Protection - A stamped, decorative metal coil
guard protects the tube-in-fin coil from debris and other damag-
ing material.
• Protected Compressor - The compressor is safeguarded
against abnormal pressures and temperatures by an internal
pressure relief valve, an internal temperature sensor, and fac-
tory high and low pressure system controls. A factory installed
liquid line filter-drier further protects the compressor against
moisture and debris.
• Environmentally Friendly Refrigerant - The next generation
refrigerant R-410A delivers environmentally friendly perfor-
mance with zero ozone depletion.
• Durable Finish - An automotive quality finish provides the ulti-
mate protection from harmful UV rays and rust creep, ensuring
a long-lasting, high quality appearance. A powder-paint topcoat
is applied over a baked-on primer using a galvanized, zinc
coated steel base material. The result is a finish that has been
proven in testing to provide 33% greater durability than conven-
tional powder-coat finishes.
• Hot Heat Pump - An optional mode that slows the indoor fan
for higher register air temperatures and premium comfort.
• WhisperDrive™ System - Features combination of swept-
wing fan, composite base pan, isolated compressor compart-
ment, and single-stage compressor to reduce overall sound to
a mere whisper. The 5-ton system utilizes a two-stage com-
pressor.
• Low RPM Fan Motor - Helps to reduce airflow noise.
• Swept Wing Fan - A fan design boasting technology adapted
from aeronautic and defense engineering provides for whisper-
quiet operation by allowing air to flow smoothly and efficiently
across the fan tips.
• Composite Base Pan - The strong and durable composite
base pan provides added strength while resisting rust and cor-
rosion, as well as reducing sound and vibration.
• Isolated Compressor Compartment - A molded composite
bulkhead isolates the refrigeration components and the com-
pressor from the rest of the unit, reducing sound and vibration.
• Lower Installed Cost - Designed to provide enhanced instal-
lability by featuring a slide-down control compartment that
allows easy access to control components, along with angled
service valves to reduce overall installation time and cost. Fac-
tory charged for a 15 foot lineset.
• Factory Installed Filter-Drier - A factory installed, solid core
liquid line filter-drier removes harmful debris and moisture from
the system.
• Easy Service Access - A full end, full service access panel
with handle makes for easy entry to internal components.
• Communications Capable - Requiring only a simple 4-wire
installation, the communicating capability enables the use of
the Touch Screen Communicating Control, allowing real time
visibility of system operation and the use of diagnostic features,
while still maintaining the ability to function with a traditional
thermostat.
• Complete System Control - These heat pumps utilize a
unique microprocessor defrost control system to provide opti-
mal comfort as well as monitor the overall system for reliable
operation. In the event improper operating conditions occur
(high temperature and/or high pressure), the system will auto-
matically shut the system down to extend the life of the heat
pump. The defrost control features an internal memory to aid
the technician in troubleshooting, reducing service time and
cost.
• Premium System Warranty* - Limited lifetime compressor
warranty when registered online within 90 days of installation.
• Agency Listed - Safety certified by CSA to UL 1995 / CSA
22.2. Performance certified to ANSI/AHRI Standard 210/240 in
accordance with the Unitary Small Equipment certification pro-
gram.
632152-CTG-E-0812

Advertisement

loading

Summary of Contents for Coleman HC6B024 THRU 060

  • Page 1 UV rays and rust creep, ensuring a long-lasting, high quality appearance. A powder-paint topcoat MODELS: HC6B024 THRU 060 is applied over a baked-on primer using a galvanized, zinc coated steel base material. The result is a finish that has been proven in testing to provide 33% greater durability than conven- tional powder-coat finishes.
  • Page 2: Physical And Electrical Data

    632152-CTG-E-0812 Physical and Electrical Data Model HC6B024F3(C) HC6B030F3(C) HC6B036F3(C) HC6B042F4(C) HC6B048F3(C) HC6B060F3(C) Unit Supply Voltage 208-230V, 1 60Hz Normal Voltage Range 187 to 252 Minimum Circuit Ampacity 17.5 17.3 22.6 23.7 26.9 33.8 Max. Overcurrent Device Amps Min. Overcurrent Device Amps Compressor Type Scroll Scroll...
  • Page 3: System Charge For Various Matched Systems

    632152-CTG-E-0812 System Charge for Various Matched Systems Outdoor Unit HC6B024F3(C) HC6B030F3(C) HC6B036F3(C) HC6B042F4(C) HC6B048F3(C) HC6B060F3(C) Required TXV 3,4,5 Additional Charge, Oz Indoor Unit AHE24B TXV + 0 – – – – – AHE30B TXV + 0 – – – – –...
  • Page 4 632152-CTG-E-0812 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING COIL UNIT MODEL NET MBH RATED MODEL MODEL WIDTH STAGE SEER TOTAL SENS. 16 SEER HP WITH AIR HANDLERS AHE24B 17.5 – – 23.8 18.0 15.00 12.50 AHE30B 17.5 –...
  • Page 5 632152-CTG-E-0812 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING COIL UNIT MODEL NET MBH RATED MODEL MODEL WIDTH STAGE SEER TOTAL SENS. 16 SEER HP WITH AIR HANDLERS 1160 47.0 30.4 AHE60D 24.5 – 15.00 11.60 1835 56.5 40.5 1090...
  • Page 6 632152-CTG-E-0812 COOLING CAPACITY - With High Efficiency Motor Furnaces FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*A12 14.5 FC/MC/PC32A 23.4 17.3 15.00 12.50 T*(8,L)V*A12 14.5 FC/MC/PC37A 23.8 17.7...
  • Page 7 632152-CTG-E-0812 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*9(C,V)*C16 21.0 FC/MC/PC43C 1030 28.8 22.2 15.00 12.50 T*9(C,V)*C20 21.0 FC/MC/PC43C...
  • Page 8 632152-CTG-E-0812 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) FURNACE COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL WIDTH SEER TOTAL SENS. 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*(8,L)V*C20 21.0 UC60C 1215 39.0 27.8 15.00 12.50 T*(8,L)X*C16 21.0 FC/MC62D...
  • Page 9 632152-CTG-E-0812 COOLING CAPACITY - With High Efficiency Motor Furnaces FURNACE COOLING UNIT COIL RATED NET MBH MODEL MODEL MODEL WIDTH STAGE SEER TOTAL SENS. 16 SEER HP WITH HIGH EFFICIENCY FURNACES 1025 46.5 29.8 20.80 T*(8,L)V*C16 21.0 FC/MC62D 15.00 1635 55.5 38.5 11.45...
  • Page 10 632152-CTG-E-0812 HEATING CAPACITY - With Air Handler Coils HEATING UNIT AIR HANDLER COIL 47F 17F HSPF RATED MODEL MODEL MODEL 16 SEER HP WITH AIR HANDLERS 23.8 3.88 1.80 15.1 2.56 1.73 8.50 AHE24B – 515* 23.4 3.63 1.92 15.1 2.56 1.73 8.40...
  • Page 11 632152-CTG-E-0812 HEATING CAPACITY - With Air Handler Coils (Continued) HEATING UNIT AIR HANDLER COIL 47F 17F HSPF RATED MODEL MODEL MODEL 16 SEER HP WITH AIR HANDLERS 1200 40.5 3.88 3.06 25.6 2.68 2.80 8.50 AHE48D – 1000* 39.5 3.98 2.91 25.8 2.86...
  • Page 12 632152-CTG-E-0812 HEATING CAPACITY - With Air Handler Coils HEATING COIL UNIT AIR HANDLER NET MBH RATED MODEL MODEL MODEL STAGE HSPF COP @ 47 47 OD 17 OD 16 SEER HP WITH AIR HANDLERS 1160 42.5 – – 3.46 AHE60D –...
  • Page 13 632152-CTG-E-0812 HEATING CAPACITY - With Upflow, Downflow, & Horizontal Furnaces and Coils (Coil Only Ratings) HEATING UNIT COIL NET MBH RATED MODEL MODEL STAGE HSPF COP @ 47 47 OD 17 OD 16 SEER HP COIL ONLY RATINGS 1350 43.5 –...
  • Page 14 632152-CTG-E-0812 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) HEATING UNIT FURNACE COIL 47F 17F HSPF RATED MODEL MODEL MODEL 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES T*9(C,V)*C20 FC/MC/PC35C 23.8 3.78 1.84 15.0 2.52 1.74 8.50 T*9(C,V)*C20 FC/MC/PC43C 24.0 4.04 1.77...
  • Page 15 632152-CTG-E-0812 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) HEATING UNIT FURNACE COIL 47F 17F HSPF RATED MODEL MODEL MODEL 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES 29.0 3.86 2.20 18.8 2.76 2.00 9.00 T*(8,L)X*C20 FC/MC/PC43C 780* 28.5 3.59 2.31 18.8...
  • Page 16 632152-CTG-E-0812 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) HEATING UNIT FURNACE COIL 47F 17F HSPF RATED MODEL MODEL MODEL 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES 1270 36.0 4.04 2.63 23.4 2.82 2.43 9.00 T*(8,L)X*C20 FC/MC/PC48C 1000* 36.0 3.44 3.27...
  • Page 17 632152-CTG-E-0812 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) HEATING UNIT FURNACE COIL 47F 17F HSPF RATED MODEL MODEL MODEL 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES 1195 41.0 4.00 3.00 25.4 2.72 2.74 8.50 T*(8,L)V*C16 UC60C 1050* 40.0 3.92 2.99...
  • Page 18 632152-CTG-E-0812 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) HEATING UNIT FURNACE COIL 47F 17F HSPF RATED MODEL MODEL MODEL 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES C*(8,L)C*C20 FC/MC62D 1365 40.5 4.06 2.92 25.8 2.74 2.76 8.50 1215 41.0 4.08 2.94...
  • Page 19 632152-CTG-E-0812 HEATING CAPACITY - With High Efficiency Motor Furnaces HEATING UNIT FURNACE COIL NET MBH RATED MODEL MODEL MODEL STAGE HSPF @ 47 47 OD 17 OD 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES 1025 41.5 – – 3.38 T*(8,L)V*C16 FC/MC62D 1635...
  • Page 20 632152-CTG-E-0812 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) HEATING UNIT FURNACE COIL NET MBH RATED MODEL MODEL MODEL STAGE HSPF @ 47 47 OD 17 OD 16 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES 1240 42.5 – – 3.54 T*9X*D20 FC/MC62D...
  • Page 21: Typical Installation

    632152-CTG-E-0812 ACCESSORIES Dehumidistat (S1-2HU16700124) - Provides increased dehu- midification when matched with variable speed furnace or air TXV Kits - S1-1TVM series thermal expansion valves precisely handler. meter refrigerant for optimum performance over a wide range of Heat Pump Risers (S1-52635389000, S1-52635390000, conditions.
  • Page 22 632152-CTG-E-0812 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B024F3(C) INDOOR COIL MODEL NO. AHX30 ID CFM 1035 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 21.7 24.2 24.1 26.2 28.4 23.9 25.3 25.2 27.3 29.5 26.1 26.4 26.3 28.5 30.5...
  • Page 23 632152-CTG-E-0812 T.C. S.C. Furnace Coil T.C. S.C. Furnace Coil T*9V*A10 FC/MC/PC37A 0.99 0.98 1.03 T*(8,L)V*A12 FC/MC/PC32A 0.99 0.95 0.99 T*9X*A10 FC/MC/PC32A 0.98 0.94 1.01 T*(8,L)V*A12 FC/MC/PC37A 1.01 0.99 0.99 T*9X*A10 FC/MC/PC37A 0.98 0.95 1.00 T*(8,L)V*B12 FC/MC/PC35B 1.00 0.97 0.98 T*9X*B12 FC/MC/PC35B 1.00 0.98...
  • Page 24: Cooling Performance Data

    632152-CTG-E-0812 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B030F3(C) INDOOR COIL MODEL NO. AHX36 ID CFM 1005 1205 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 27.5 29.6 29.7 32.4 35.6 29.4 30.7 30.7 33.7 36.7 31.4 31.8 31.8 35.0...
  • Page 25 632152-CTG-E-0812 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B036F3(C) INDOOR COIL MODEL NO. AHX42 ID CFM 1000 1200 1400 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 34.1 36.2 36.4 39.6 43.0 36.1 37.4 37.5 40.8 44.1 38.1 38.5 38.5...
  • Page 26 632152-CTG-E-0812 T.C. S.C. Furnace Coil T.C. S.C. Furnace Coil T*9X*C16 UC48C 1.01 1.03 0.95 T*(8,L)V*C16 FC/MC/PC48C 0.99 0.99 0.93 T*9X*C16 UC60C 0.99 1.04 0.94 T*(8,L)V*C16 FC/PC60C 1.01 1.01 0.93 T*9X*C20 FC/MC/PC48C 0.99 0.99 0.93 T*(8,L)V*C16 UC48C 1.00 1.00 0.94 T*9X*C20 FC/PC60C 1.00 1.00...
  • Page 27 632152-CTG-E-0812 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B042F4(C) INDOOR COIL MODEL NO. AHE60 ID CFM 1185 1385 1585 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 39.3 41.5 41.5 45.3 49.4 41.1 42.5 42.5 46.4 50.6 42.9 43.5 43.5...
  • Page 28 632152-CTG-E-0812 T.C. S.C. Furnace Coil T.C. S.C. Furnace Coil T*9X*C16 UC60C 0.98 1.01 1.00 T*(8,L)V*C16 FC/MC62D 1.00 1.02 1.06 T*9X*C20 FC/MC62D 1.01 1.04 1.03 T*(8,L)V*C16 FC/PC60C 0.97 0.96 0.98 T*9X*C20 FC/PC60C 1.00 1.00 0.99 T*(8,L)V*C16 UC60C 0.97 0.97 0.98 T*9X*C20 UC60C 0.97 0.97...
  • Page 29 632152-CTG-E-0812 COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B048F3(C) INDOOR COIL MODEL NO. AHX60 ID CFM 1400 1600 1800 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 45.7 48.6 48.5 52.9 58.0 47.6 49.7 49.6 54.2 59.4 49.4 50.9 50.8...
  • Page 30 632152-CTG-E-0812 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC6B060F3(C) INDOOR COIL MODEL NO. AHX60 ID CFM 1730 1930 2130 CONDENSER ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 56.5 59.8 59.9 65.4 70.1 58.4 60.9 60.8...
  • Page 31: Heating Performance Data

    632152-CTG-E-0812 HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B024F3(C) INDOOR COIL MODEL NO. FC/MC/PC35 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 OUTDOOR UNIT INDOOR COIL 29.1 4.30 1.98 30.4 4.69 1.90 31.6 5.12 1.81 28.3 3.78 2.20 29.4 4.12 2.09 30.5...
  • Page 32 632152-CTG-E-0812 HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B030F3(C) INDOOR COIL MODEL NO. FC/MC/PC43 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 OUTDOOR UNIT INDOOR COIL 34.9 4.32 2.37 35.6 4.54 2.30 36.2 4.77 2.22 34.2 3.84 2.61 34.9 4.04 2.53...
  • Page 33 632152-CTG-E-0812 HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B036F3(C) INDOOR COIL MODEL NO. FC/MC/PC48 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 1400 OUTDOOR UNIT INDOOR COIL 43.8 4.26 2.99 44.0 4.63 2.76 44.1 5.09 2.52 42.9 3.74 3.33 43.2 4.07...
  • Page 34 632152-CTG-E-0812 HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B042F4(C) INDOOR COIL MODEL NO. FC/MC62 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1200 1400 1600 OUTDOOR UNIT INDOOR COIL 48.88 4.87 2.94 50.3 5.05 2.92 51.8 4.89 2.95 46.8 4.29 3.20 48.1 4.45...
  • Page 35 632152-CTG-E-0812 HEATING PERFORMANCE DATA OUTDOOR UNIT MODEL NO. HC6B048F3(C) INDOOR COIL MODEL NO. FC/MC62 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1400 1600 1800 OUTDOOR UNIT INDOOR COIL 61.1 4.66 3.84 61.2 4.75 3.78 61.3 4.84 3.71 58.8 4.02 4.29 59.1 4.12...
  • Page 36 HEATING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. HC6B060F3(C) INDOOR COIL MODEL NO. FC/MC62 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1650 1850 2050 OUTDOOR UNIT INDOOR COIL 72.6 4.30 4.94 73.3 4.42 4.86 74.1 4.55 4.77 71.1...