PARAMETER
Nominal Input Voltage
Factory Preset
By changing internal
jumper position
Input Current
At 120 VAC input
At 230 VAC input
Output Voltage, VDC
Absorption / Boost, "Uo"*
Float / Maintenance, "U"*
Maximum Bulk Charging Current, I
Normal operation
Half Power Mode
Threshold of Current for Change Over
From Float "U" to Boost "Uo"
From Boost "Uo" to Float "U"
Duration for Absorption or
Boost Stage, Uo
Temperature Compensation
Wired Remote Panel (Optional)
Cooling
Protections
Overload
Short Circuit
Reverse polarity
Thermal overload
Output Banks
Output Connector
Operating Temperature Range
Input Power Cord (Attached)
Fuses
AC Input Side (6 mm x 30 mm; Slow Blow Type)
For 120 VAC input
For 230 VAC input
DC Output Side (Automotive Blade Type, e.g. Bussmann "ATC")
In parallel
Dimensions (L x W x H), mm
Weight
Notes: * The charging voltages shown are applicable at battery temperature of 80
The above specifications are subject to change without notice

SPECIFICATIONS

SEC-1260A
120 VAC/50-60 Hz
(105 to 125 VAC)
230 VAC/50-60 Hz
(207 to 253 VAC)
13.6A
6.8A
14 V/14.4 V +/-0.05 V
13.5 V +/-0.05 V
60 A
30 A +/-1 A
8.5 A +/-1 A
6 A +/-0.5 A
4 Hours or 8 Hours
(Switch selectable)
Yes. With sensor TF-500
Yes. Model 900-RC
By fan
Yes
Yes
Yes
Yes
2
Tubular hole (dia 8 mm) with set screw
o
0
C to 40
15A, NEMA5-15 plug
15 A / 250 V
8 A / 250 V
32 V, 35 A x 2 pcs.
330 x 230 x 108
4 Kg
Page 28
o
C
o
F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sec-1280aSec-2440a