ANUAL РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES AIR CONDITIONER REMOTE CONTROLLER (WIRED TYPE) Remote Controller UTH-3TA16 SU MO TU WE TH FR SA 3 6 9 12 15 18 21 KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9373329053-01...
CONTENTS SAFETY PRECAUTIONS ..........1 WEEKLY TIMER ............. 6 NAME OF PARTS ............1 TEMPERATURE SET BACK TIMER ....... 8 FUNCTION INFORMATION ........... 2 SELF-DIAGNOSIS ............9 PREPARATORY OPERATION ......... 3 OPERATING TIPS ............9 OPERATION ..............3 TROUBLESHOOTING ..........10 ON/OFF TIMER ...............
FUNCTION INFORMATION Depending on the indoor unit model, some buttons on this remote controller cannot be used and some functions are re- stricted. Refer to the following table for the buttons that can be used for each model. : Button can be operated : Button cannot be operated Button numbers (refer to page 1) Model...
PREPARATORY OPERATION To set the current day and time Press the DAY button and select the current day. appears around the selected day. DAY OFF CLOCK ADJUST Press the TIMER MODE button for 2 seconds or more. The time display on the remote controller will flash.
Page 5
OPERATION To set the operation mode G Vertical air direction adjustment (Swing operation) * Press the START/STOP button to start the air conditioner, and then proceed as follows. Press the VERTICAL AIRFLOW DIRECTION button to adjust the direction of the verti- cal airflow.
OPERATION Room temperature sensor selection THERMO SENSOR Indoor unit Press the THERMO SENSOR button to select whether the room temperature is detected at the indoor unit (remote sensor) or the remote controller. When the thermo sensor display appears, the room temperature is detected at the remote controller.
WEEKLY TIMER Instructions related to heating are applicable to “HEAT PUMP MODELS” and “HEAT RECOVERY MODELS” only. The timer function is not available depending on the model. To set the WEEKLY timer SU MO TU WE TH FR SA CLOCK ADJUST 3 6 9 12 15 18 21 Press the SET button for 2 seconds or Press the TIMER MODE button to select the weekly timer.
Page 8
WEEKLY TIMER To start/cancal the WEEKLY timer operation G To start G To cancel SU MO TU WE TH FR SA DELETE CLOCK ADJUST 3 6 9 12 15 18 21 • Press the DELETE button to cancel 3 6 9 12 15 18 21 the timer mode.
TEMPERATURE SET BACK TIMER Instructions related to heating are applicable to “HEAT PUMP MODELS” and “HEAT RECOVERY MODELS” only. The timer function is not available depending on the model. To set the temperature SET BACK timer SET BACK SU MO TU WE TH FR SA If there is no existing SET BACK tempera- ture setting, “- -”...
SELF-DIAGNOSIS When the error indication “E:EE” is displayed, inspection of the air conditioning system is necessary. Please consult author- ized service personnel. (1) Stop the air conditioner operation. Faulty unit number (remote controller address) Error code SU MO TU WE TH FR SA SU MO TU WE TH FR SA ex.
If the problem persists after performing these checks, or if you notice burning smells, immediately stop operation, turn off the electrical breaker and consult authorized service personnel. SPECIFICATIONS REMOTE CONTROLLER (WIRED TYPE) DIMENSIONS & WEIGHT MODEL POWER HEIGHT [mm] WIDTH [mm] DEPTH [mm] WEIGHT [g] UTH-3TA16 DC 12 V En-10...