Mitsubishi Electric MSZ-GC22VA Service Manual page 16

Split-type, heat pump air conditioners
Hide thumbs Also See for MSZ-GC22VA:
Table of Contents

Advertisement

2. Indoor unit failure mode table
Upper lamp of OPERATION
INDICATOR lamp
Not lighted
Room temperature
1-time flash
thermistor
every 0.5-second
2-time flash
Indoor coil thermistor
2.5-second OFF
3-time flash
Serial signal
2.5-second OFF
11-time flash
Indoor fan motor
2.5-second OFF
12-time flash
Indoor control system
2.5-second OFF
NOTE : Blinking patterns of this mode differ from the ones of Troubleshooting check table (10-4.).
Abnormal point
(Failure mode)
Normal
The room temperature thermistor short
or open circuit is detected every 8 seconds
during operation.
The indoor coil thermistor short or open
circuit is detected every 8 seconds during
operation.
The serial signal from outdoor unit is
not received for 6 minutes.
The rotational frequency feedback signal is
not sent out for 12-seconds after indoor fan
motor is opeated.
It cannot properly read data in the
nonvolatile memory of the indoor electronic
control P.C. board.
Condition
Refer to the characteristics of the room
temperature thermistor (10-7.).
Refer to the characteristics of the main
indoor coil thermistor, the sub indoor coil
thermistor (10-7.).
Refer to 10-6.D "How to check mis-wiring
and serial signal error".
Refer to 10-6.A "Check of indoor fan
motor".
Replace the indoor electronic control
P.C. board.
16
Correspondence