EPSON Stylus CX1500/ME100
4.3.6 Housing Upper
V External View
Hook
Figure 4-17. Housing Upper Removal
DISASSEMBLY AND ASSEMBLY
Housing Upper
C.P.F 3x8
TBD
(4±0.5kgfcm
V Part/Unit that should be removed before removing Panel Housing/Housing
Upper.
Document Cover / Panel Unit / Panel Housing / Scanner Unit
V Removal procedure
1.
Remove the screws (x4,
2.
While removing Housing Upper in the upward direction, release connector
cables secured to the hook (x1,
Do not damage all connector cables.
C A U T I O N
Disassembly
Revision A
) for securing Housing Upper.
).
86