Occurrence
timing
Detailed phenomenon
CR position
The drive of the PF Motor is not
transmitted to the LD Roller Shaft.
The LD Roller is not set to the ASF
home position and paper is always
loaded from the ASF Unit during the
• Operation
paper loading sequence.
Although the printer enters standby
mode normally after power-on, the PF
Motor does not rotate when a print job is
transmitted to the SPC.
TROUBLESHOOTING
Table 3-6. Check point for the paper out error according to each phenomenon
Defective
unit/part name
1. Check if the Compression Spring 1.764 does not come off
in the Change Lever.
Ink System Unit
1. Check if the tip of the Change Lever is not damaged.
Ink System Unit
1. Check if the PF Motor Connector Cable is connected to
J9 on the Main Board.
PF Motor
2. Check if the coil resistance of the PF Motor is about 6.1Ω
by using tester
3. Check if the PF Motor Connector Cable is not damaged.
Troubleshooting
Check point
Change Lever
Compression Spring 1.764
PF Motor
J9
Connector Cable
(refer to Table
3-1).
Revision A
Remedy
1. Replace the Ink System Unit with a new one.
1. Replace the Ink System Unit with a new one.
1. Connect the PF Motor Connector Cable to J9
on the Main Board.
2. Replace the PF Motor with a new one.
3. Replace the PF Motor with a new one.