Connecting the mains supply cable

o The mains terminal block is located on the rear of the oven and
the terminals are accessible by removing the terminal block
cover. You should remove the cover screw to access this.
o The cable connections must be made in accordance with the
diagram below:-
o 1, 2 and 3 are the live connection, 4 and 5 are the neutral
connection and the remaining one is the earth connection.
o The live wire MUST be placed in connection number 1.
The neutral wire MUST be placed in connection number 4.
The earth wire MUST be placed in the connection marked with
the
symbol.
o The brass links must be positioned as marked in the diagram
above and once established ALL terminal screws must be
tightened down firmly.
o If when the oven is first switched on, it does not function
correctly, you should recheck that the terminal screws are
all fully tightened between the links. This should be done
before contacting the Customer Care Department.
o IMPORTANT: The appliance must NOT be connected to the
mains supply by means of a 10 or 15 Amp plug and socket.
o The cable can be looped if necessary, but make sure that is not
kinked or trapped when the oven is in position. Care must be
taken to avoid the cable being in contact with hot parts of the
appliance.